Once derating factor is considered the size of cable for perticular electrical load increased by the multipling factor.i,e if 2.5MM2 cable is capable to carry 14amp. of current in general then with 40% of derating fator it can carry only 8.4amp.
air flow speed
derating
although the AC signal is rectified the output which we get is the pulsating DC which is not desired because many appliances wok on plain DC voltage . The pulsating DC can be viewed as AC + DC component of the signal ripple factor of a rectified circuit is the ratio of AC component of signal to the DC component of the same rectified output signal. higher the ripple factor says that the signal is not smooth so lesser is its application. the components used to smooth these type of signals or to remove the 'ripple voltage' as called filters
DC is used for extra-high voltage transmission systems, as there are less losses with DC than with AC, and no synchronising problems.
batteries derating factor will change ,depends upon the temperature& cable size which arelinked with batteries bank.
Once derating factor is considered the size of cable for perticular electrical load increased by the multipling factor.i,e if 2.5MM2 cable is capable to carry 14amp. of current in general then with 40% of derating fator it can carry only 8.4amp.
air flow speed
derating
in case of dc losses are very less than in case ac,as power factor is 1
A transistor rating that tells how much the maximum allowable value of PD decreased for each 1°C rise in ambient temperature.
Power factor is an AC only term, and has no meaning for DC.
You can put three ccc's in a conduit (any size conduit) before you derate. Keep in mind that for single phase loads (lighting, receptacles) the neutral is also counted as a current carrying conductor. This derating factor does not apply to nipples 24 inches long or less. See NEC Table 310.15(B)(2)(a) for full details on derating regarding ccc's.
Derating factor depends on ambient temperature & how u r laying the cable ie., in Air,Duct,Burried. normally the current carring capacity of a perticular cable is calculated at 40*c, but if u lay the cable in air then it includes the temparture around it,if it increases more the 40*c then the conductor gets heated up by increasing the resistance in it thus the current carring capacity of a given cable decreases, so we will derate the cable The derating factor of induction motor is the ratio of the calculated output power to the rated power
it is only work on it so that used
dc series motor is used for traction...
although the AC signal is rectified the output which we get is the pulsating DC which is not desired because many appliances wok on plain DC voltage . The pulsating DC can be viewed as AC + DC component of the signal ripple factor of a rectified circuit is the ratio of AC component of signal to the DC component of the same rectified output signal. higher the ripple factor says that the signal is not smooth so lesser is its application. the components used to smooth these type of signals or to remove the 'ripple voltage' as called filters