Derating factor depends on ambient temperature & how u r

laying the cable ie., in Air,Duct,Burried.

normally the current carring capacity of a perticular cable

is calculated at 40*c, but if u lay the cable in air then

it includes the temparture around it,if it increases more

the 40*c then the conductor gets heated up by increasing

the resistance in it thus the current carring capacity of a

given cable decreases, so we will derate the cable

The derating factor of induction motor is the ratio of the

calculated output power to the rated power

User Avatar

Wiki User

14y ago

What else can I help you with?

Continue Learning about Electrical Engineering

How many current carrying conductors are allowed in a raceway before derating?

You can put three ccc's in a conduit (any size conduit) before you derate. Keep in mind that for single phase loads (lighting, receptacles) the neutral is also counted as a current carrying conductor. This derating factor does not apply to nipples 24 inches long or less. See NEC Table 310.15(B)(2)(a) for full details on derating regarding ccc's.


What ampacity column are you allowed to use for derating using thhn wire?

When derating THHN wire, you typically refer to the ampacity column in the National Electrical Code (NEC) Table 310.16 (or its equivalent in local codes). This table provides the allowable ampacity for various wire types at different temperature ratings and installation conditions. For derating, you'll adjust the ampacity based on the number of conductors in a raceway, ambient temperature, and insulation type, ensuring compliance with NEC guidelines. Always consult the latest version of the NEC and local amendments for accurate information.


What are the causes of derating of cables?

1. We consider cable de-rating factor, because the method of laying of cable either in air, duct or trench, affect the current carrying capacity as dissipation of heat in air is more than in duct or trench. Now the factors that causes derating are 1. ambient temperature (this is the average temperature of the plant). If surrounding temperature is higher than cable temperature at which it is designed then that increase the resistance of cable conductor which decreases the current 2. Number of cables in cable tray either they are touching each other or at a distance. If cables are touching each other, they created dielectric field around them which in case of touching causes interference with one another that causes resistance to increase. 3. No. of cable trays in a tier.


In the UK what cable should you use for a domestic ring main?

The cable usually used is 2.5mm2 three core (live, neutral and earth). In circumstances where the cable runs are long or derating is required due to temperature 4mm2 is used. The ring main is usually protected by a 32A circuit breaker. In older installations a 30A fuse was used.


What size wire for 600 amp 480 v 3 phase?

For a 600 amp, 480 V, 3-phase system, you would typically use 3/0 AWG copper wire or 250 kcmil aluminum wire, depending on the installation conditions and applicable code requirements. It's essential to consider factors such as the length of the run, ambient temperature, and any derating factors that may apply. Always consult the National Electrical Code (NEC) or a qualified electrician for specific applications and local regulations.

Related Questions

What is derating factor of battery?

batteries derating factor will change ,depends upon the temperature& cable size which arelinked with batteries bank.


What is current value after derating factor considered?

Once derating factor is considered the size of cable for perticular electrical load increased by the multipling factor.i,e if 2.5MM2 cable is capable to carry 14amp. of current in general then with 40% of derating fator it can carry only 8.4amp.


The calculation used to determine amperage of a conductor based on the total number of conductors in a conduit is called A derating B voltage drop C conduit fill D conductor fill?

derating


How do you calculate derating factor for cables?

The derating factor for cables is calculated by considering various environmental factors such as ambient temperature, grouping of cables, and installation conditions. First, determine the cable's current-carrying capacity based on its specifications. Then, apply correction factors from relevant standards or tables for each influencing factor, multiplying these factors together to obtain the overall derating factor. Finally, multiply the original capacity by the derating factor to find the adjusted capacity for safe operation.


What is derating factor in case of diesel engines?

air flow speed


What information can be found on a wire derating chart?

A wire derating chart provides information on how much current a wire can safely carry based on factors such as wire size, insulation type, and ambient temperature.


How many current carrying conductors are allowed in a raceway before derating?

You can put three ccc's in a conduit (any size conduit) before you derate. Keep in mind that for single phase loads (lighting, receptacles) the neutral is also counted as a current carrying conductor. This derating factor does not apply to nipples 24 inches long or less. See NEC Table 310.15(B)(2)(a) for full details on derating regarding ccc's.


What is derating of motor?

Derating of a motor refers to the practice of operating the motor at a lower capacity than its maximum rated load to enhance reliability and longevity. This adjustment can account for various factors such as higher ambient temperatures, frequent starts and stops, or specific application requirements. By derating, the motor is less likely to overheat and experience premature failure, ultimately ensuring better performance and efficiency in demanding conditions.


Definition of derating?

The verb derating means to assess the value of (some types of property, such as agricultural land) at a lower rate than others for local taxation; operation of a machine at less than its rated maximum power in order to prolong its life.


How many current carrying conductors can you have in a conduit before you have to start derating amparage?

The number of current-carrying conductors allowed in a conduit before derating is specified by the National Electrical Code (NEC). Generally, if you have more than three conductors in a conduit, you need to start derating the ampacity of the conductors. Specifically, for more than three conductors, the ampacity of each conductor must be reduced based on the number of conductors present. For example, with 4 to 6 conductors, the ampacity is typically reduced to 80%, and with 7 to 9 conductors, it’s reduced to 70%.


What ampacity column are you allowed to use for derating using thhn wire?

When derating THHN wire, you typically refer to the ampacity column in the National Electrical Code (NEC) Table 310.16 (or its equivalent in local codes). This table provides the allowable ampacity for various wire types at different temperature ratings and installation conditions. For derating, you'll adjust the ampacity based on the number of conductors in a raceway, ambient temperature, and insulation type, ensuring compliance with NEC guidelines. Always consult the latest version of the NEC and local amendments for accurate information.


What is the meaning of derating factor?

A transistor rating that tells how much the maximum allowable value of PD decreased for each 1°C rise in ambient temperature.