The capacity of a TXV differs due to orifice size, pressure difference between high and low side, and the temperature and condition of the refrigerant in the liquid line.
Difference between txv and exv.
It could be restriction or low charge. Meaning you could have a bad txv valve or not enough refrigerant in the system.
The Txv usaully will not let any flow though valve causing low side to pump down or go off on low pressure. Because it is the charge that opens the diaphragm/valve against the spring pressuse (keeps the valve closed) of the TXV, an absense of the charge will allow the spring pressure to keep the valve closed; consequently starving the evaporator coil of a saturated vapor, until the system pulls down into a vacuum. If the system is equiped with a low side pressure switch, the system should go off on low pressure.
No, it is not.
Metering device The metering device controls the flow of liquid refrigerant through the system. The liquid enters at a high-pressure, high-temperature, sub-cooled state and leaves as a low-pressure, low temperature, expanded liquid state. Accurator Piston and Thermostatic Expansion Valves are the most widely used metering devices. Accurator Pistons are widely used because of their low cost and flexibility. The piston can easily be changed to match the capacity of the condensing unit. The Thermostatic Expansion Valve (TXV) is the most efficient type of metering device. The TXV automatically adjusts the flow of the liquid refrigerant based on the superheat of the refrigerant leaving the evaporator coil. As the load on the evaporator increases, the TXV increases the flow of refrigerant. This maintains the proper superheat. The TXV is efficient throughout a variety of system operating conditions, while the accurator is efficient only under designed conditions.
The evaporator changes refrigerant from a low pressure liquid to a low pressure vapor, and acts as a heat exchanger, removing heat and humidity from the passenger compartment.
Dual port TXV used when system need a large TXV for short periods of time. Dual-port valves have two independent capacities larger port for periods of high load smaller port for periods of normal load TXV capacity is doubled when larger port is open all the way.
spring
step motor
step motor
COULD BE MANY THINGS- NEED MORE SPECIFICS. MOST LIKELY TXV OR CHARGE ISSUE. IF TEMP RISE GOOD IN H/P MODE W/O STRIP OR SUPP. HEAT ADDED MOST LIKELY TXV. IS OA TEMP AN ISSUE THIS TIME OF YEAR? (LOW HEAD PRESSURE) lc