Well I'm not hundred percent sure of that but as long as I am aware it should remain a '7' because it's still neutral meaning pure water just heated up a little and if it does happen to change then I believe it would be a 8 ranging towards basic not acidic.
Boiler feed is the fresh or treated water to replenish the water loss though evaporation or leak
Function - It adds the pressure to the feed water before it entyers into boiler feed pump suction Advantage - Ensures high margin NPSH A for boiler feed pump spinning at high rpm (5250Rpm) Drive for booster - Normally @1450 rpm Type of impeller- Mostly preferred Double suction
In boiler feed water line the NRV is normally installed between Pump and stop valve if the line is short and an another NRV is installed at boiler entrance and after stop valve if the line is long or pump is 10 to 15 m away from the boiler.
Use of water in a refinery is makeup for boiler feed. The chief uses of steam are for stripping, steam distillation, and vacuum distillation. The steam comes in contact with the products in these operations, and generally the steam condensate is so highly contaminated that it cannot be reused for boiler feed or for other purposes. Steam is also used for process heating, for pumping, and, in some refineries, for generating electric power
Water tube boilers are used in marine and stationary applications. A water tube boiler heats by water flowing through tubes and being heated by fire externally.
the pH value in boiler feed water is 9.2
generally pH of d.m water i.e. out from mixed bed exchanger is 6-7.5. but the boiler feed water criteria is different. hence before feeding to the boiler again pH and electrolites checked.
dear, both morpholine and hydrazine or ammonia are used in conjunction. morpholine is a base which is used for adjusting the PH of boiler feed water.
Making up feed with water having low PH. Feed water getting contaminated with sea water, greese, fatty/fuel oils, CO2, 02 can cause water to become acidic leading to boiler corrosion as well as redusing it PH value. Lot of leakage will also cause more make up water and if regular blow down is not carried out, will cause increase in total disolve solides, thus reducing PH. Also if boiler water treatment is not carried out properly can result in drop in PH.
C4h9no is not remove gases only boost ph.
Boiler feed pumps are an important part of any boiler operation. They control the amount of water fed to the boiler and the manner in which it is fed.
Boiler feed is the fresh or treated water to replenish the water loss though evaporation or leak
To control the alkalinity of boiler water which is directly related to pH control. Too alkaline will cause stainless steel to brittle while too low alkalinity will cause corrossion.
A digester feed pump forces water to a boiler. It works by transferring cool water to the boiler to be heated.
Function - It adds the pressure to the feed water before it entyers into boiler feed pump suction Advantage - Ensures high margin NPSH A for boiler feed pump spinning at high rpm (5250Rpm) Drive for booster - Normally @1450 rpm Type of impeller- Mostly preferred Double suction
Oils and water are not miscible.
1ppb for O2 and CO2