answersLogoWhite

0


Want this question answered?

Be notified when an answer is posted

Add your answer:

Earn +20 pts
Q: What is relation between flow rate and actuator speed?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

How does bleed off flow control differ from meter in and meter out?

meter in: regulates the speed of the actuator by controling the amount of fluid entering in to the actuator. meter out: regulates the speed of the actuator by controling the amount of fluid leaving the actuator. bleed off: regulates the speed of the actuator by metering a part of the pump flow to the tank. Prof. Mahesh Chopade MIT College of Engineering, Pune


What is the relation between light and current?

One relationship is that both can flow in vacuum.


What is the relation between viscosity and flow ability of a material?

The higher the viscosity, the lower the flow-ability of a material.(Viscosity=internal resistance to flow)


What is the relation between viscosity and flow-ability of a material?

The higher the viscosity, the lower the flow-ability of a material.(Viscosity=internal resistance to flow)


What is relation between mass flow rate and discharge pressure in reciprocating compressor?

These have a inverse relation. You will need to know the discharge and the incoming pressure in order to find out the mass flow rate.


What is the relation between current and thikness of conductor?

The thicker the conductor, the less the current that will flow through.


How do you select hydraulic actuator?

pump selection requires many factors like the flow rate requirements, speed , pressure,cost ,maintenance, performance,reliability. step1: find out what type of actuator your are going to use depending on the type of loading .cylinder type actuator or a rotary type actuator like a hydraulic motor. step2: find out the flow rate requirements depending upon the distance through which the load is to be moved in a specified time limit. step3: find out the pressure requirements depending upon the magnitude of the load and the size of the actuator.now along with the flow rate you can find the power requirement of the pump and select the prime mover do drive the pump. step4:find out the speed of the pump and along with flow rate calculations determine the pump size. step5: gear ,vane and piston are the types of pump available for the fluid power applications.there are many subtypes available for these pumps. gear pump= 500-3000 psi,1200-2500 rpm,efficiency 80-90 ,flow capacity 1-200 gpm vane pump=1000-2000 psi,speed 1200-1800 rpm, efficiency 80-95, flow capacity 1-80gpm piston pump=2000-12000 psi, speed 1200-3000 rpm, efficiency 85-98,flow capacity 1-200 gpm. apart from these determine the power losses etc.,


What is difference between flow rate and flow velocity in flow tubes?

velocity is the speed of the flow (for example, meters/sec.) Flow rate is the volume per unit time (example: liters/sec.)


How do you convert water flow in litres per min to pressure in bar?

The relationship between pressure and flow is given by Bernoulli's law. In an idealized system, the speed increases with the square of the increase in pressure. The flow rate would be given by multiplying the area of the outflow by the speed.


What is the function of pneumatic valves?

If you are talking about a pneumatic solenoid valve the function of it is to control the air in and out flow in a pneumatic actuator.


How do antitrust laws affect the circular flow of the free market?

They speed up the flow of capital and wages


How is the heater actuator replaced on a 2003 Ford Explorer?

The temperature actuator motor controls the flow of air through the heater core. The motor is located under the driver's side dash, above the transmission tunnel. It's a little difficult to get to, but not bad. Check heatertreater.net for pictures and what to check for on the actuator motor.