An electrical breaker is dual function an electrical fuse just has one purpose.
If you are describing a circuit breaker then its electromagnetic trip component will operate in the event of a line*-to-ground (*not 'phase'!) short circuit. The thermal overload component will only operate in the event of a sustained overload.
A circuit breaker is an automatically operated electrical switch designed to protect an electrical circuit from damage caused by overload or short circuit. Its basic function is to detect a fault condition and, by interrupting continuity, to immediately discontinue electrical flow. Unlike a fuse, which operates once and then must be replaced, a circuit breaker can be reset (either manually or automatically) to resume normal operation. Circuit breakers are made in varying sizes, from small devices that protect an individual household appliance up to large switchgear designed to protect high voltage circuits feeding an entire city.Types:MCB (Miniature Circuit Breaker)-rated current not more than 100 A. Trip characteristics normally not adjustable. Thermal or thermal-magnetic operation. Breakers illustrated above are in this category.MCCB (Molded Case Circuit Breaker)-rated current up to 2500 A. Thermal or thermal-magnetic operation. Trip current may be adjustable in larger ratings.Fuses - These come in various sizes and make ups. The downside is most fuses need replacing after tripping.
IMO it would be because the circuit breaker has the possibility of going bad and not working (allowing a short to move through the device), but fuses blow (cause a break) no matter what if shorted.
handling the circuit breaker
An advantage of a thermal printer is printing speed and quality. A disadvantage of a thermal printer is the higher cost.
MCB (Miniature Circuit Breaker)-rated current not more than 100 A. Trip characteristics normally not adjustable. Thermal or thermal-magnetic operation. Breakers illustrated above are in this category.MCCB (Molded Case Circuit Breaker)-rated current up to 2500 A. Thermal or thermal-magnetic operation. Trip current may be adjustable in larger ratings. MCB (Miniature Circuit Breaker)-rated current not more than 100 A. Trip characteristics normally not adjustable. Thermal or thermal-magnetic operation. Breakers illustrated above are in this category.MCCB (Molded Case Circuit Breaker)-rated current up to 2500 A. Thermal or thermal-magnetic operation. Trip current may be adjustable in larger ratings.from Manu anand
As far my knowledge goes the only difference i found in a thermal magnetic relase & microprocessor based was in a microprocessor based Circuit breaker we have a additional protection i.e. for Earth fault. Aparts that the range of fault setting in a microprocessor based circuit breaker is more than in a thermal magnetic trip unit.
A fuse is a one-time device; once it is used, it is no good. A breaker can be reset.
The best advantage of thermal power is the price. It is a much cheaper way to produce electricity.
Headlights have a thermal circuit breaker. A short to the headlight (positive to ground) will cause the breaker to trip. The breaker cools and the lights come back on till the breaker heats up. Find the short and fix it.
An advantage of a thermal printer is printing speed and quality. A disadvantage of a thermal printer is the higher cost.
An electrical breaker is dual function an electrical fuse just has one purpose.
If you are describing a circuit breaker then its electromagnetic trip component will operate in the event of a line*-to-ground (*not 'phase'!) short circuit. The thermal overload component will only operate in the event of a sustained overload.
Miniature circuit breakers are smaller & easier to instal. It occupy less space & are more efficient
Operating a breaker on a continuous current, close to the breaker's tripping point can cause this condition. Because the breaker is a thermal device the heat builds up over a time period. Check the breakers on either side of the faulting breaker. If these breakers are also warm from use they take away the heat sink effect and do not let the faulting breaker cool down. Check the current of the load to see how close you are operating to the breakers trip point. Over time the trip setting of the breaker can become lower to a point where it will not reset. Changing the breaker out should rectify this non resetting condition.
One of the main advantage of using a Diesel engine as opposed to a regular is that a Diesel engine tends to burn less fuel. They also have very high thermal efficiency.