The purification in molecular sieve chromatography is dependent on the size of the molecules. The small molecules will enter into pores of gel while large molecules will be excluded from the pores.

User Avatar

Wiki User

βˆ™ 11y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What is the basis of molecular sieve chromatography?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What is molecular exclusion chromatography?

molecular exclusion chromatography is the exclusion or separation of protein particles based on their molecular size. Bhubanyu Basu


A list of molecular compounds in household?

mplecular sieve 13 X


How does gas chromatography separate substances?

On the basis of their solubility in particular substances.


Which type of molecular sieve is the best for VPSA oxygen generating unit?

Molecular sieves are the β€œheart” of the VPSA-O2 system. The main performance requirements for the molecular sieves used for the VPSA oxygen plant are excellent adsorption performance, high yield, stable oxygen purity, uniform particle size, high solidity & abrasion resistance and long service life. The better the performance of the molecular sieve is, the larger the scale of a single set of VPSA oxygen equipment would be achieved. Commonly used molecular sieve adsorbents are 5A, 10X, 13X, N-2, CaA, NaX, CaX, LiX, CNA-198, Li.X.RE, HX5A-980, etc. Taking the common CaA molecular sieve as an example, when the air passes through the adsorption tower equipped with CaA molecular sieve, N2 is adsorbed preferentially so that the oxygen flows out of the adsorption tower as the product gas because the quadrupole moment of nitrogen is much larger than that of oxygen and the Ca2+ on the surface of the CaA molecular sieve micropore is more effective in adsorbing N2 than adsorbing O2. However, the adsorption capacity and selectivity of CaA molecular sieve adsorbent for nitrogen are still not high enough, resulting in low oxygen yield and high energy consumption of VPSA oxygen generation units. Compared with CaA and NaX molecular sieve adsorbents, LiX molecular sieve has higher oxygen production efficiency. Less LiX molecular sieve could be used for the same oxygen capacity, thus reducing the energy consumption and size of the VPSA and PSA oxygen generator. LiLSX molecular sieve's capacity for adsorbing nitrogen is greater than its capacity for adsorbing the oxygen component of air with a higher degree of Li-ion exchange and smaller radius of Li+. The number of Li+ in liLSX molecular sieve is twice that of Ca2+ in CaA molecular sieve adsorbent and nitrogen & oxygen separation coefficient is 2-5 times that of the traditional oxygen molecular sieves, which enables lithium molecular sieve to adsorb more nitrogen. When applied to VPSA & PSA oxygen units, the consumption of liLSX molecular sieve is only 1/4-1/5 that of CaA molecular sieve, which is conducive to lowering the total investment, increasing the oxygen yield and greatly reducing the power consumption. Compared with ordinary molecular sieve, PU-8 lithium-based molecular sieve independently developed and manufactured by PKU Pioneer has a higher absorption capacity for nitrogen, and the nitrogen-oxygen separation coefficient is 8-10, which is the highest in China at present. PKU Pioneer's PU-8 oxygen adsorbent has been applied to 300+ VPSA & PSA oxygen generation units. Due to its higher oxygen yield, less loading amount of PU-8 adsorbent helps to minimize the operating load of the supporting power equipment, which substantially reduces the comprehensive investment and operating energy consumption of VPSA oxygen systems. At the same time, PKU Pioneer's exclusive mechanical homogeneous spin loading technology ensures uniform distribution of the adsorbent. After primary loading, no replacement or refilling is required within 10 years under normal usage without the capacity decrease of the oxygen unit caused by the adsorbent pulverization. Based on PU-8 oxygen adsorbent, PKU Pioneer's complete sets of VPSA oxygen devices have been widely used in iron & steel, non-ferrous metallurgy, glass & glass fiber, cement, pulp making, waste incineration, new energy batteries, refractory materials and other industrial fields to help customers optimize existing processes and achieve energy saving & profit lifting.


Would you that mixing gases is a reversible change?

It isn't easily reversible but, it is reversible. You can use a molecular sieve or a distillation column to separate them.


What is the molecular basis of type 1 diabetes?

There basis of Type 1 diabetes has to do with the dysfunction of the beta cells of the pancreas and their inability to produce insulin. If there were a molecular basis it would be the absence of insulin which helps the body tissues utilize glucose.


What difference does chromatography rely on to separate out parts of solution?

Different molecular sizes apex


What are the molecular basis of living organisms?

DNA. Witch can replicate and it does.


Can you use chromatography to get lumps out of cake mix?

Chromatography is not an appropriate means of getting lumps out of cake mix. You should use a sifter or sieve to get lumps out of a dry cake mix. After liquid ingredients are added, you should use a whisk, a hand mixer or an electric mixer to break up any lumps.


Define the four ways to separate a mixture?

by boiling point: distillation by molecule / particle size: electrophoresis/sieve/membrane by polarity or charge: chromatography/isoelectric focussing by specific gravity: centrifugatiuon


Differences between living and non living on the molecular basis?

none


What are disadvatages of chromatograph?

chromatography has many varieties -paper chromatography, sometime complexe mixtures cant be separated, TLC plates do not have long stationary phases -gaz chromatography: the molecule should be volatile -Chiral Chromatography can be expensive - Ion Exchange or Ion Chromatography: Turbidity should be low below 10ppm -Size Exclusion Chromatography: low resolution technique which gives few peaks and requires large differences in molecular weight for resolution -Gel chromatography: the target protein frequently becomes an abundant substrate for proteases that may also be present in the mixture. Another disadvantage is low sample handling.