Drainage fittings and pressure fittings are worlds apart, despite both dealing with fluids. Here's the key difference:

Pressure Management: Pressure fittings are designed for pressurized systems. They can handle fluids flowing under constant pressure, like those in hydraulic systems or water supply lines. Their robust construction and tight seals ensure leaks don't occur even under forceful flow.

Gravity's Flow: Drainage fittings, on the other hand, are built for waste removal. They handle fluids like wastewater or rainwater that move by gravity, not constant pressure. These fittings prioritize smooth flow and capturing debris, often featuring wider openings and looser connections compared to pressure fittings.

While they might look similar, their functionalities are distinct. Drainage fittings keep waste flowing freely, while pressure fittings ensure pressurized fluids stay contained.

User Avatar

Brand. sealexcel

Lvl 3
4d ago
This answer is:
User Avatar
More answers
User Avatar

Wiki User

14y ago

Drainage fittings have pitch and are not pressure rather

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What is the difference between a drainage fitting and a pressure fitting?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What is the difference between schedule and class?

schedule is the thickness of the pipe and class is pressure/temperature rating of a fitting or pipe


How do you define the coefficient of incipient cavitation?

The cavitaion index across a valve or pipe fitting is defined as the ratio of difference between upstream pressure and vapor pressure to the pressure drop across the valve or fitting. The index at which incipient cavitation, damage, or choked flow occurs is based on testing and depends on the type of valve or fitting.


What is the difference between JIC hydraulic fittings and a sae flare fitting?

JIC and SAE flare are two common types of hydraulic fittings, but key differences set them apart. Here's a breakdown: Angle of Attack: The most significant distinction lies in the sealing surface angle. JIC fittings utilize a 37-degree flare, while SAE flare fittings typically have a 45-degree angle. This seemingly small difference translates to significant variations in sealing pressure and interchangeability. Pressure Rating: JIC fittings generally boast higher pressure ratings compared to their SAE counterparts. The 37-degree angle creates a tighter seal, allowing JIC fittings to handle higher fluid pressures within a hydraulic system. Material and Application: JIC fittings are primarily made from robust materials like steel for their high-pressure capabilities. They're commonly found in industrial and construction applications where high pressures are a norm. SAE flare fittings, often made from brass, can handle moderate pressures and are frequently used in refrigeration and air conditioning systems. Interchangeability: Due to the different flare angles, JIC and SAE fittings are not directly interchangeable. Mixing them can lead to leaks and potential system failure. However, there's a caveat. SAE J514, a specific type of SAE flare fitting, also utilizes a 37-degree angle and might be interchangeable with JIC fittings in certain situations. It's crucial to consult the manufacturer's specifications for confirmation. In conclusion, JIC and SAE flare fittings serve different purposes. JIC excels in high-pressure applications, while SAE caters to moderate pressure needs. Understanding the angle, pressure rating, and material differences is key to selecting the right hydraulic fitting for your specific needs.


What is a cast iron drainage tee?

A cast fitting that is shaped like a TEE and used either for drainage or venting


Where is low pressure ac access fitting for 2002 Chevy pickup?

The LOW pressure fitting is SMALLER than the HIGH pressure fitting.


What is defrence between fitting NACE material A105?

what is the difference between A105 and A105 Nace


What is the difference between curve fitting and regression?

curve fitting is a very difficult and time wasting method while regrresion is more to use as compare to curve fitting


How does selection of fitting is done with respect to pipe?

long radus fittings on drainage


Where is the fuel pressure test port in1992 Chevy Suburban?

It doesn't have one. To test the fuel pressure an adapter has to be installed between a fitting at the fuel filter and the fuel filter, preferably the fitting feeding into the filter from the pump.


Difference between coupling and pipe union?

A coupling is a threaded or soldered solid fitting, a union is a fitting that joins two pipes and can be taken apart with wrenches.


What is the difference between a street and a regular fitting?

STREET has male and female ends REG has only female


What is difference between tube connector and tube adapter fitting?

A tube connector is the standard fitting that goes on a tube or hose. A tube adapter fits to a tube or hose and enables it to connect to a fitting of a different size to its standard.