There are 2 types of smoke detectors: ionization detectors and photoelectric detectors. Although they use different mechanisms both essential set off an alarm when smoke obscures the line of sight between 2 objects within the detector.
Yes, there are different types of smoke alarms, and choosing the right one for your home is a crucial part of effective smoke alarm installation. The main types of smoke alarms are ionization and photoelectric smoke alarms, and there are also dual-sensor alarms available. Ionization smoke alarms are more responsive to fast-burning fires, while photoelectric smoke alarms are better at detecting smoldering fires. Dual-sensor smoke alarms combine both technologies, offering comprehensive protection. When determining which type of smoke alarm to install during the smoke alarm installation process, consider the specific fire risks in your home. For instance, if you have a kitchen with cooking appliances, a photoelectric smoke alarm may be more suitable, as it is less likely to be triggered by cooking-related smoke. In areas prone to smoldering fires, such as near a fireplace, a photoelectric alarm is an excellent choice. For the most comprehensive protection, you might opt for dual-sensor smoke alarms. These are designed to detect a wide range of fire types effectively. Remember, during the smoke alarm installation process, follow the manufacturer's instructions for placement and spacing to ensure the alarms cover your home adequately. The right choice of smoke alarm type, along with proper installation, will greatly enhance the fire safety in your home.
Most smoke detectors work either by optical detection (photoelectric) or by physical process (ionization), while others use both detection methods to increase sensitivity to smoke. For the alarm part, in many single family detached and smaller multiple family housings, a smoke alarm is often powered only by a single disposable battery. An optical detector is a light sensor. When used as a smoke detector, it includes a light source (incandescent bulb or infrared LED), a lens to collimate the light into a beam, and a photodiode or other photoelectric sensor at an angle to the beam as a light detector. In the absence of smoke, the light passes in front of the detector in a straight line. When smoke enters the optical chamber across the path of the light beam, some light is scattered by the smoke particles, directing it at the sensor and thus triggering the alarm. An ionizing detector type of detector is cheaper than the optical detector; however, it is sometimes rejected because it is more prone to false alarms than photoelectric smoke detectors. It can detect particles of smoke that are too small to be visible. It includes about 37 kBq or 1 µCi of radioactive americium 241, corresponding to about 0.3 µg of the isotope. The radiation passes through an ionization chamber, an air-filled space between two electrodes, and permits a small, constant current between the electrodes. Any smoke that enters the chamber absorbs the alpha particles, which reduces the ionization and interrupts this current, setting off the alarm. From Wikipedia.
A fire alarm turns on when the sensor senses heat nearby while a burglar alarm senses movement or forced entry from a specific area it is guarding..
If you have factory alarm, you have a right light blinking in the dashboard (on the top of the light there is word "alarm") when the alarm is on. If you have aftermarket alarm, then the blinking light is usually to left of the steering wheel next to mirrors regulator.
Remainder is what is left over from a mathematical calculation Reminder is an alarm for a date or a meeting
A clock radio and an alarm clock are two very similar things which provide some of the same functions however they differ in their features. An alarm clock is a basic clock which has an alarm function and a clock radio combines the use of an AM/FM radio and an alarm clock.
It's used in smoke detectors. It ionizes the air in the detector, and the electrons displaced by the ionization flow between two plates. Smoke disrupts this flow, the detector sees the change in current as proof of a fire and sounds the alarm.
Photoelectric detectors are best used for detecting smoke and fire in various settings such as homes, offices, and public buildings. These detectors work by detecting the presence of smoke particles in the air, triggering an alarm and allowing prompt action to be taken. They are particularly effective in detecting smoldering fires, which may produce more smoke before flames are visible.
http://resources.alibaba.com/topic/800023062/Carbon_monoxide_gas_detector_and_the_difference_between_combustible_gas_detector.htm This website gives you all the information about the differences between the two systems.
the fire door is usually rigged with an alarm that in some cases immediately calls the fire department
With an older alarm clock ... one with hands on the front and a wind-up key in the back ... you get one (1) hour of sleep, because the clock doesn't know the difference between AM and PM. With a more modern LED digital clock, you get thirteen (13) hours; the display has that little dot on the side, so you can tell the difference between AM and PM when you're setting the time or the alarm.