What is the power line voltage between phase and earthing?

Updated: 8/19/2019
User Avatar

Wiki User

13y ago

Best Answer

It is the same as phase to neutral. As the neutral is earthed at the electricity suppliers transformer.

User Avatar

Wiki User

13y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What is the power line voltage between phase and earthing?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What is difference between 0.8 leading and 0.8 lagging power factors?

Power factor measures the phase difference between voltage and current. If they are in phase the Power Factor is one. If the current and voltage are out of phase the power factor is between zero and one. You can describe the PF by saying the current lags the voltage with a PF = .8 or the voltage leads the current with a .8 PF.


How do you wire a 110 V DB board from a 220 V 3 phase transformer supply?

In a wye system the voltage between any two wires will always give the same amount of voltage on a three phase system. However, the voltage between any one of the phase conductors (X1, X2, X3) and the neutral (X0) will be less than the power conductors. For example, if the voltage between the power conductors of any two phases of a three wire system is 220v, then the voltage from any phase conductor to ground will be 110v. This is due to the square root of three phase power. In a wye system, the voltage between any two power conductors will always be 1.732 (which is the square root of 3) times the voltage between the neutral and any one of the power phase conductors. The phase-to-ground voltage can be found by dividing the phase-to-phase voltage by 1.732 answer from ground and any phase


What is the power factor of an resititive load?

Power factor is the cosine of the phase angle between voltage and current. In a resistive load, current is in phase, i.e. with a phase angle of 0 degrees, with respect to voltage. Cosine (0) is 1.


Phase difference between voltage and current at resonance?

The power factor is a measure of the phase difference. If they are exactly in phase the PF = 1. If they are 180 degrees out of phase PF = 0.


How power is flowing when voltage and phase angle is maintained same?

Assume you are saying that the current and voltage are in phase and you want to know how power is affected. When Voltage and Current are in phase the Power Factor is 1 and you have maximum power being applied. When Voltage and Current are not in phase, Power Factor decreases from 1 toward zero.


What is neutral earthing?

Neutral earthing are grounding options available for both low and medium voltage power systems. It provides point of zero volts.


Is 220V line voltage or phase voltage?

Phase, if you are referring to line, as power line from pole.


How can you find the power factor?

Power factor is the cosine of the phase angle between voltage and current. It is also KW/KVA.


How do you connect an earthing transformer with delta connected secondary?

You have to connect each phase (R,Y & B respectively) of earthing transformer zig zag winding to each phase of power transformer delta secondary respectively. Then the zig zag winding of earthing transformer star point to be earthed.


What is meant by three phase?

Three phase power is a method of electric power transmission using three wires. Three phase power systems may have a neutral wire that allows the system to use a higher voltage while still allowing lower voltage single phase appliances. In high voltage distributions, it is not common to have a neutral wire, as the loads can simply be connected between phases.


How can a tuned RC circuit improve the power factor of an inductive motor circuit?

The RC circuit can reduce the phase shift between the voltage and current in the power line. The phase shift is caused by the inductance of the motor. The phase shift between the voltage and current in the power line causes problems due to the presence of so called imaginary current or power that does no work but must be supplied by the power source.


What is the Phase to neutral voltage on a 400 volt 3 phase power supply?

The line-to-neutral (not 'phase-to-neutral'!) voltage on a 400V 3-Phase wye-connected system is 230V.Line voltage is the voltage as measured between any two (2) line conductors (hence its name!). Line voltage is often referred to as the 'line-to-line voltage'.Phase voltage is the voltage as measured between any single line and neutral. Phase voltage is often referred to as a 'line-to-neutral' voltage."400V" on a 400V 3-Phase wye-connected power supply indicates its line voltage. Line voltage in a wye system is always the phase voltage multiplied by the square-root of "3" (1.732) and reflects the vector sum of two individual phase voltages present in a three phase system.Thusly, if the line voltage is "400V", then the phase voltage is 400V divided by the square-root of "3" (1.732), which is 230V.Examples of this for North American power systems are 120/208V, 277/480V and 347/600V. Examples for other areas of the world are 220/380V, 230/400V and 240/415V.