answersLogoWhite

0


Best Answer

50 percent

User Avatar

Wiki User

13y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What is the relative humidity when the dry-bulb temperature is C and the wet bulb temperature is C?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Natural Sciences

How do you use a wet bulb thermometer and a dry bulb thermometer?

as the air passes over the wet bulb thermometer the water in the cloth evaporates. as the water evaporates the cloth cools. if the humidity is low the water will evaporate more quickly and the temperature reading on the wet bulb thermometer will drop. if the humidity is high only a little bit of water will evaporate from the cloth of the wet bulb thermometer and the change in temperature will be small.


What happens to the humidity as the differences of the dry and wet bulb increase?

the relative humidity will decrease.


How do you calculate relative humidity from actual humidity?

Answeractuall humidity is given as the amount of water. use a table stating how much water the air can hold at the given temp, this is your 100% humidity. now calculate howw much you got and that would be relative humidityAnswer:To calculate relative humidity you need a wet bulb and a dry bulb thermometer and a psychrometric chart (a graph of the physical properties of moist air at a constant pressure). The chart graphically expresses how various properties relate to each other.Using an ordinary thermometer you read the dry bulb temperature(DBT). You will locate this temperature on the x-axis of the chart.Next you will determine the wet bulb temperature (WBT) from a thermometer who's bulb is covered with a wet wad of cotton and typically waved in the air until the temperature goes to its minimum. This works because dry air evaporates water and evaporation cools the wad. The temperature it reaches is related to the air's humidity. This value goes on the curved line at the top of the chart.The relative humidity (RH) is read off the chart from the intersection of the lines from these two points.


How does the difference between the dry bulb temperature and the wet bulb temperature to the relative humidity?

When the humidity in the surrounding air is low, the water in the wet cloth wrapped around the bulb of the "wet bulb" thermometer evaporates quicker, giving lower reading on that thermoneter, thus widening the gap between the wet bulb and dry bulb temperatures. The lower the humidity in the air, the quicker the evaporation, the lower the "wet bulb temperature".


Wet bulb temp is really what temp outside?

Typically wet bulbs are used to give a heat-index or what it "feels like" outside. Because humans cool themselves by sweating, wet bulbs attempt to factor in humidity and wind speed to approximate the effective temperature while sweating. The wet bulb temperature is also used, together with the dry bulb temperature, to determine the relative humidity. If you know the relative humidity, you can calculate the difference with an equation given at: http:/en.wikipedia.org/wiki/Heat_index

Related questions

What is the dew-point when the dry bulb temperature is 20C and the relative humidity is 17?

at 17% relative humidity the dew point is -5.8C at a dry bulb of 20C


When wet bulb temperature and dry bulb temperature are equal?

for air water system wet bulb equals to dry bulb at 100 % relative humidity for that given temperature of air.


What is the significance of wet bulb temperature?

dry bulb temperature simply tells us the temperature of dry air.but the comfort also depends on humidity ie. water vapour presents in the air.Wet bulb temperature measures the humidity in the air.Because the evaporation of water in the bulb wick depends on the relative humidity of surrounding air.


What step should you follow to measure humidity with a psychrometer?

A sling psychrometer (or hygrometer) uses the difference in readings between a wet bulb thermometer and another with a dry bulb to measure the relative humidity. The bulb that is wet will cool by evaporation to the "dew point", which is the temperature at which the current humidity would be the maximum possible. Comparing that to the dry bulb (the general air temperature) on a comparative chart will yield the approximate relative humidity.


What is the relative humidity of a room having a dry bulb 72 degrees F and a wet bulb temperature of 59 degrees F?

answer is


On a cold winter day the air temperature is 2C and the wet-bulb temperature is -1C What is the relative humidity at this location?

51%.... open to the Relative Humidity chart in the reference tables. the wet bulb temperature is -1C and the dry bulb temp. is 2C, making a difference of 3C. On RH chart, go down to 3C column (difference between the Wet bulb and dry bulb) until it intersects the dry bulb 2C. At this intersection is 51%


How would you use a wet bulb thermometer and a dry bulb thermometer to find the relative humidity?

You would use both to determine the relative humidity.


How do you use a wet bulb thermometer and a dry bulb thermometer?

as the air passes over the wet bulb thermometer the water in the cloth evaporates. as the water evaporates the cloth cools. if the humidity is low the water will evaporate more quickly and the temperature reading on the wet bulb thermometer will drop. if the humidity is high only a little bit of water will evaporate from the cloth of the wet bulb thermometer and the change in temperature will be small.


What happens to the humidity as the differences of the dry and wet bulb increase?

the relative humidity will decrease.


What is the instument used to find relative humidity?

barometer A barometer measures atmospheric pressure, not humidity. A hygrometer measures humidity.


How do you calculate relative humidity from actual humidity?

Answeractuall humidity is given as the amount of water. use a table stating how much water the air can hold at the given temp, this is your 100% humidity. now calculate howw much you got and that would be relative humidityAnswer:To calculate relative humidity you need a wet bulb and a dry bulb thermometer and a psychrometric chart (a graph of the physical properties of moist air at a constant pressure). The chart graphically expresses how various properties relate to each other.Using an ordinary thermometer you read the dry bulb temperature(DBT). You will locate this temperature on the x-axis of the chart.Next you will determine the wet bulb temperature (WBT) from a thermometer who's bulb is covered with a wet wad of cotton and typically waved in the air until the temperature goes to its minimum. This works because dry air evaporates water and evaporation cools the wad. The temperature it reaches is related to the air's humidity. This value goes on the curved line at the top of the chart.The relative humidity (RH) is read off the chart from the intersection of the lines from these two points.


How does the difference between the dry bulb temperature and the wet bulb temperature to the relative humidity?

When the humidity in the surrounding air is low, the water in the wet cloth wrapped around the bulb of the "wet bulb" thermometer evaporates quicker, giving lower reading on that thermoneter, thus widening the gap between the wet bulb and dry bulb temperatures. The lower the humidity in the air, the quicker the evaporation, the lower the "wet bulb temperature".