minimize congestion, stability margin improvement, line overload reduction, power flow control
This applies to three-phase transformer connections. 'Phase shift' or 'angular displacement', is defined as 'the angle by which the secondary line-to-line voltage lags the primary line-to-line voltage'.Angular displacement depends on the type of transformer connection. The most common are:delta/delta results in an angular displacement of 0o or 180owye/wye results in an angular displacement of 0o or 180odelta/wye results in an angular displacement of 30o or 210owye/delta results in an angular displacement of 0o or 180oThe angular displacement for all possible combinations of three-phase transformer connections are listed in transformer vector group charts.Angular displacement determines whether or not it would be possible to parallel different types of three-phase transformer connections. For example, from the above data, it would be impossible to parallel, for example, a delta/delta transformer with a delta/wye transformer.
yes
the necesscity of two three phase transformers operating in parallel are as follows...if the one transformer fails to give supply,then another transformer can be used in parallel and hance,continuity of supply can be maintained.one transformer can be easily take out from the supply for repair & maintanance.if the load on the substation increases beyond the rated values of transformer, then another transformer can be used to share rhe load of the substation.
Rephrase your question. As it stands, it makes no sense.
Yes, you can use three single phase transformers on three phase applications and interconnect them to serve as a single transformer or you could use one single phase transformer fed from two of the three lines in a step down application.
This depends on the voltage, and whether it is a three phase or single phase transformer.
Nothing. The same rating is applicable.
Use a transformer.
If the primary and the secondary windings of the three phase transformer are connected in delta, you cannot get a healthy neutral from it but why bother? You simply drive a rod into earth and use it as a neutral. Alternatively either the primary or the secondary windings must be connected as star and you use the common point as neutral.
Through the use of the basic transformer voltage equation.
If these are the exact voltages that you need you will need an auto transformer to obtain these voltages. If these voltages are nominal voltages and are of a three phase four wire configuration, the 220 voltage can be obtained from the three phase legs to the neutral (ground) connection. The equation to use is 400/1.73 = 231 volts.
The basic difference is the secondary voltages. On a distribution transformer the secondary voltage is very high. This is to overcome line loss for transmission of electricity over long distances. A three phase power transformer is used at the consumers three phase services end to manipulate voltages that consumers need to operate their equipment. The transformer that feeds your house is considered to be a single phase power transformer.