The primary winding is connected to the supply. The secondary winding is connected to the load. A tertiary winding (if used) is a third winding, which may be connected in various ways.
If the transformer is a three-phase transformer, then there are three common configurations: wye (also known as 'star'), delta (also known as 'mesh'), and zig-zag.
When working on a current transformer the secondary windings must be shorted. <<>> Properly loaded
Core transformer and shell transformer - it has a one window. - it has a two windows. - less mechanical protection - better mechanical protection to the coils. to the coils. -windings encircles the core. - core encircles the winding. - cylindrical windings are used. - sandwich type windings are used. - it is easy to repair. - it is not easy to repair.
A step-up transformer needs more turns on the secondary windings than on the primary windings to increase the voltage.
The dc tests that can be done on a transformer are to measure the resistance of each windings and to measure the insulation resistance between the windings and between each winding and the transformer case.
If this refers to a wire wound transformer, as it sounds then there is likely only two possibilities : the input voltage has dropped prier to entering the primary windings or there is a short in the windings some where within.The only other possibility I can think of is : This is a trick question and the transformer is a step down transformer.
Clarify your question. What do you mean by 'type' of winding?
Transformer has windings
The # of windings in a transformer are based on the primary and secondary voltages the transformer is rated for not the way the windings are connected.
When working on a current transformer the secondary windings must be shorted. <<>> Properly loaded
it has three primary windings & three secondary windings.
The container the transformer core and windings are placed inside is the tank.
Core transformer and shell transformer - it has a one window. - it has a two windows. - less mechanical protection - better mechanical protection to the coils. to the coils. -windings encircles the core. - core encircles the winding. - cylindrical windings are used. - sandwich type windings are used. - it is easy to repair. - it is not easy to repair.
If a transformer has 20 primary windings and 100 secondary windings, it is a step up transformer. If the secondary voltage is 25v, the primary voltage will be 5v, because the turns ratio is 20 to 100, or 1 to 5.
They have both.
A step-up transformer needs more turns on the secondary windings than on the primary windings to increase the voltage.
Transformer step-up/step-down voltage is turns-ratio, so if a transformer has 20 primary windings and 100 secondary windings (a turns-ratio of 1 to 5) and the secondary voltage is 25, then is the primary voltage is 5.
Physicially it has transformer tank, conservator, bucholz relay , windings, oil