Best Answer

The difference in frequency would cause the compressor to operate out of its design limits. It would not cool properly and fail prematurely.

User Avatar

Melvin Bayer

Lvl 10
1y ago
This answer is:
User Avatar
More answers
User Avatar

Wiki User

14y ago

If transformer is made to operate 60Hz instead of 50 Hz... a> The output of the transformer will increase . Because the voltage induced in the secondary is directly proportional to the frequency. b> There will an increase in hysteresis loss which is number of repetition of the hysteresis loop per cycle.As the cycle will increase and hence the repetition. c> Eddy current loss will increase .Eddy current loss which is directly proportional to the square of the frequency find a new frequency and hence loss increase. d> Increase in skin effect (negligible).

This answer is:
User Avatar

User Avatar

Wiki User

15y ago

The eddy current loss is directly proportional to frequency. So when frequency increases the loss increases.

This answer is:
User Avatar

User Avatar

Wiki User

14y ago

The difference in frequency would cause the compressor to operate out of its design limits. It would not cool properly and fail prematurely.

This answer is:
User Avatar

User Avatar

Wiki User

14y ago

99% of all systems work fine on either. Televisions can be the exception. We even run 400 hz systems on 60 hz once in awhile.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What will happen when you will operate a 50 hertz machine with 60 hertz generator?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Engineering

What does 50 hertz or 60 hertz mean in an electrical generator?

The unit hertz means "cycles per second" and is a measure of the frequency of variation of anything which changes during a set period of time, including electric current and voltage. Saying that a generator of electricity runs at 50 hertz means that its current and voltage changes regularly at a rate of 50 times per second. Saying that a generator of electricity runs at 60 hertz means that its current and voltage changes regularly at a rate of 60 times per second. The Hertz value can be changed on the generator by increasing or decreasing the speed (RPM) of the prime mover. The generator has a feed back unit that monitors the frequency and automatically applies more power to the prime mover if the load increases and the generator RPM starts to slow down. The reverse happens if the load drops off and the generator starts to speed up, the power to the prime mover will be reduced. On a diesel generator it is the fuel flow that is increased and decreased to keep the frequency at a constant value. On a water turbine it is the water flow that is increased and decreased to keep the frequency at a constant value.


What is a 400 hertz generator mean?

It's a generator that creates 400hz AC signals, instead of 50 or 60hz. 400hz is often used on ships, because the equipment (generators, transformers) can be made much smaller.


What is the meaning of rpm of the turbine?

RPM stands for Revolutions Per Minute so, in short, RPM is the number of revolutions that the generator shaft turns in one minute. It seems obvious that the question is really trying to understand RPM vs frequency in Hertz. To understand this, you need to know the number of poles in the rotating and/or stationary magnetic field. In a two pole generator, for instance, an RPM of 1800, or 30 RPS (Revolutions Per Second), yields 60 Hertz power. In a eight pole generator, for instance, an RPM of 450, or 7.5 RPS, yields 60 Hertz power. The equation is simple... FHertz = SRPM / 60 * PNumber of Poles


Can you run a 460 volt 3 phase 60 hertz refrigeration compressor on 460 volt 3 phase 50 hertz?

Possibly. You need to check the rating on the device. Many compressors can operate on either 50 or 60 Hz.


What the letters MHz mean?

The M is short for Mega, which is 1 million. The Hz is short for Hertz, the measure of frequency. MHz is therefore short for Mega Hertz, or 1 million Hertz.

Related questions

What can happen if you connect a 60 hertz air conditioning unit to a 50 hertz generator?

Probable the air conditioner doesn't work well.


Will AC 220-240v 50hz battery charger work in America?

No, the U.S. electrical system is 60 hertz not 50 hertz. The only way you can use it is if the charger will operate at 50 & 60 hertz which is unlikely but possible. It will be listed on the charger if it will operate at a lower hertz.


220 volts 60 hertz to 220 volts 50 hertz?

Original Answer:If the power was being generated by a generator all that has to be done is slow the RPM of the generator down until the frequency meter reads 50 Hertz. On a hydro site it would be the same scenario by slowing the turbine down.Improved Answer:changing frequency is one of the more difficult things to do. Decreasing the speed of a generator is not a practical answer if the power comes from grid. You can use a variable frequency drive, or a motor generator set (Where the motor is rated for 60HZ, and the Generator is rated at 50 Hertz).For practical purposes, just get rid of the 50 hertz device and buy a new one.


Why 115 volts and 400 hertz used in modern aircrafts?

Generator design.


What frequency does an airplane generator use?

An aircraft uses 400 Hertz generators.


What does 50 hertz or 60 hertz mean in an electrical generator?

The unit hertz means "cycles per second" and is a measure of the frequency of variation of anything which changes during a set period of time, including electric current and voltage. Saying that a generator of electricity runs at 50 hertz means that its current and voltage changes regularly at a rate of 50 times per second. Saying that a generator of electricity runs at 60 hertz means that its current and voltage changes regularly at a rate of 60 times per second. The Hertz value can be changed on the generator by increasing or decreasing the speed (RPM) of the prime mover. The generator has a feed back unit that monitors the frequency and automatically applies more power to the prime mover if the load increases and the generator RPM starts to slow down. The reverse happens if the load drops off and the generator starts to speed up, the power to the prime mover will be reduced. On a diesel generator it is the fuel flow that is increased and decreased to keep the frequency at a constant value. On a water turbine it is the water flow that is increased and decreased to keep the frequency at a constant value.


Can you operate a 120V 60 hertz tv on 120V 50 hertz?

no because the tv can only pick up siginals at 60Hz if the signal is 50 Hz it won't pic it up.


What rental car companies operate in London?

In London there is several rental car companies that operate. Some of these are: Hertz, Avis, Rentalcars, Vipcars, Europcar, Arguscarhire and Enterprise.


How many hertz are in a Playstation?

In America we use 60 hertz power. It is changed to d.c. to operate the unit. Their processors run at high frequencies. Many megahertz. You have to know which system to know that frequency.


What is the ats consolidated inc?

mine was platepass from hertz rentacar. toll charge machine i used.


What is a 400 hertz generator mean?

It's a generator that creates 400hz AC signals, instead of 50 or 60hz. 400hz is often used on ships, because the equipment (generators, transformers) can be made much smaller.


Can a 60 cycle motor work okey ina 50 cycle setting?

CHANGING FREQUENCY FROM 50HZ TO 60HZ HAVE THE FF. EFFECT IN THE ELECTRICAL AND MECHANICAL PARAMETERS; a. MOTOR RATED HP OR KW WILL HAVE A increase OF ABOUT 10% b. FULL LOAD RUNNING TORQUE WILL decreace ABOUT 8%