Want this question answered?
When changing liquid refrigerant into a system
The refrigerant plays a key role in achieving vapor cycle air ... After that, and until all the water has been evaporated, the remaining boiling liquid stays at the ... of the higher temperature of boiling resulting from increased pressure.
Yes. The basic components of the refrigeration system are the refrigerant, compressor, condenser and receiver, expansion device and the evaporator. One cycle: Refrigerant travels to Compressor (A) to Condenser (B) to Expansion device (C) to evaporator (D). The refrigerant gas at low pressure and temperature is drawn into the compressor. The gas is compressed to a higher pressure, which causes an increase in the temperature. The refrigerant gas at a high pressure and temperature passes to the condenser (point B), where it is cooled (the refrigerant gives up its latent heat) and then condenses to a liquid. The high pressure, low temperature liquid is collected in the receiver. The high pressure liquid is routed through an expansion valve (point C), where it undergoes an abrupt reduction in pressure. That pressure reduction causes part of the liquid to immediately vaporize or flash. The vapor and remaining liquid are cooled to the saturation temperature (boiling point) of the liquid at the reduced pressure. At this point most of the refrigerant is a liquid. The boiling point of the liquid is low, due to the low pressure. When the liquid refrigerant enters the evaporator (point D), it absorbs heat from the process and boils. The refrigerant gas is now at low pressure and temperature, and enters the suction side of the compressor, completing the cycle.
burns
burns
Liquid refrigerant charging of a system is normally accomplished in the liquid line. For example, when a system is out of refrigerant, liquid refrigerant can be charged into the king valve on the liquid line or receiver.
Liquid
When changing liquid refrigerant into a system
Vaporizing the refrigerant
The liquid refrigerant that is banned is CFC. It destroys the ozone.
The refrigerant plays a key role in achieving vapor cycle air ... After that, and until all the water has been evaporated, the remaining boiling liquid stays at the ... of the higher temperature of boiling resulting from increased pressure.
Yes. The basic components of the refrigeration system are the refrigerant, compressor, condenser and receiver, expansion device and the evaporator. One cycle: Refrigerant travels to Compressor (A) to Condenser (B) to Expansion device (C) to evaporator (D). The refrigerant gas at low pressure and temperature is drawn into the compressor. The gas is compressed to a higher pressure, which causes an increase in the temperature. The refrigerant gas at a high pressure and temperature passes to the condenser (point B), where it is cooled (the refrigerant gives up its latent heat) and then condenses to a liquid. The high pressure, low temperature liquid is collected in the receiver. The high pressure liquid is routed through an expansion valve (point C), where it undergoes an abrupt reduction in pressure. That pressure reduction causes part of the liquid to immediately vaporize or flash. The vapor and remaining liquid are cooled to the saturation temperature (boiling point) of the liquid at the reduced pressure. At this point most of the refrigerant is a liquid. The boiling point of the liquid is low, due to the low pressure. When the liquid refrigerant enters the evaporator (point D), it absorbs heat from the process and boils. The refrigerant gas is now at low pressure and temperature, and enters the suction side of the compressor, completing the cycle.
To endure that the ONLY gas in the system is refrigerant.
FLASH GAS - Instantaneous evaporation of some liquid refrigerant at the metering device due to pressure drop which cools the remaining liquid refrigerant to desired evaporation temperature.This flash gas cannot absorb any heat having a negative effect on the net refrigeration cycle
FLASH GAS - Instantaneous evaporation of some liquid refrigerant at the metering device due to pressure drop which cools the remaining liquid refrigerant to desired evaporation temperature.This flash gas cannot absorb any heat having a negative effect on the net refrigeration cycle
It cools the liquid refrigerant after it is compressed from gas to a liquid from the compressor.
Your recharge your air conditioner with the type of refrigerant which it was designed for.