Why are oc and sc tests preferred when compared to sumpners test?

OC and SC tests are used for predetermining the efficiency and % voltage regulation. It is more efficient test for a transformer than sumpner's test for 2 reasons. 1. two identical transformers are readily not available 2. two separate power supplies are required for the sumpner's test, whereas OC and SC are simple and best


What are the advantages of OC and SC test compared to load test?

> Predetermination of regulation. > Predetermination of efficiency. > Less power loss.


How many forward castes are there in andhra pradesh?

OC Polinativelamas OC Komati OC Reddy OC Brahmin OC Mahammadeeyulu OC Acharyulu OC Gujarathi OC Marwadies OC Sikhs OC Muslim OC Islam OC Telaga OC Kapu OC Thoti OC Karanam OC Velama OC Vysya OC Naidu OC Kamma OC Chowdary OC Raju OC Jain OC Gupta OC Agarwal OC Mudiliyar OC Adi Velama OC Christian OC Gajula Kapus OC Kshatriya


How will you justify in taking oc test input as iron loss?

Taking open circuit (OC) test input as iron loss is justified because the OC test is performed under no-load conditions, where the core of the transformer is energized, but there is minimal current flow in the windings. This allows for the measurement of losses primarily due to hysteresis and eddy currents in the core material, which are classified as iron losses. Since these losses occur regardless of the load, the OC test effectively isolates and quantifies the iron losses, facilitating accurate transformer performance analysis.


Why oc test done in lv side?

In OC test , the equipments are connected in LV side since we need to get rated voltage . if it is cinnected in HV side the value of voltage will be less and current wil be more.Hence the ordinary instruments cannot measure this value of current