See the diagram linked below.
A shunt DC motor connects the armature and field windings in parallel or shunt with a common D.C. power source. This type of motor has good speed regulation even as the load varies, but does not have the starting torque of a series DC motor
A shunt-wound DC motor can maintain its speed well when the load torque varies.
A series motor respond by decreasing its speed with small increase in current for a given load torque. A shunt motor holds its speed nearly constant with large increase in input current for same amount of load torque
A shunt motor isn't literally constant-speed; its speed does fall between no load and full load. If you plot a graph of speed against load, you will find that the speed falls by around 10% or so. Compared with other d.c. motors, this fall is considered to be insignificant -hence the term, 'constant speed'.We apply a similar term to transformers, when we describe them as being 'constant voltage' machines. They're not literally 'constant voltage', but their regulation (difference between full-load and no-load voltage), is considered to be insignificant.
load test on dc shunt generator is a test to plot the internal and external characteristics of the generator.
A shunt DC motor connects the armature and field windings in parallel or shunt with a common D.C. power source. This type of motor has good speed regulation even as the load varies, but does not have the starting torque of a series DC motor
Motor will rotate at very high speed leading to destructionAnswer from Kinindia.com
on adding load on a dc shunt motor, the amount of current and torque will increase. but terminal voltage will decrease
Shunt motor is used. For constant speed ,torque will high when load is increased
The torque on a series motor is determined by the square of the armature current and, so, is very large -much larger than that of a shunt motor. Consequently, on starting, with no back-emf being generated, the torque on a series motor can be dangerously high if the machine has no mechanical load.
the basic difference is ,in short shunt motor the series field winding wont carry any current under no load condition whereas in long shunt motors series winding will carry no load current.....
in this test their is a no load on dc shunt motor so it is an indirect test
A shunt-wound DC motor can maintain its speed well when the load torque varies.
Yes. In order to do work, there has to be a load. In order for there to be current, there has to be a load. Now, that is probably not what you meant to ask. If so, please restate the question correctly.
A series motor respond by decreasing its speed with small increase in current for a given load torque. A shunt motor holds its speed nearly constant with large increase in input current for same amount of load torque
.The magnitude of the voltage and current of both the armature and shunt field coil. To decrease the speed when the load is increasing then increase the shunt field current while decreasing the armature voltage or current. To increase the speed while the load is increasing then increase the armature current while decreasing the shunt field current. The decreasing and increasing of these currents and voltages can be done by connecting a variable resistor in series or parallel with each of the armature and/or shunt field coil.
Because the field flux is constant.