answersLogoWhite

0

Where would you fine the fire panel?

User Avatar

Anonymous

13y ago
Updated: 8/20/2019

in the sout

User Avatar

Wiki User

13y ago

What else can I help you with?

Related Questions

What is a fire alarm panel?

Mimic panel in fire alarm system 'mimics' or mirrors the signal of the Main Fire Control Panel.


How a mimic panel works in fire alarm system?

Mimic panel in fire alarm system 'mimics' or mirrors the signal of the Main Fire Control Panel.


Why would fuse box panel on car catch fire?

Answer 1 - Fuse Panel FireThe cause is/was a "SHORT CIRCUIT" condition on the "incoming" [from the battery] side of the fuse panel.


What is the minium size branch circuit for a fire alarm system?

Are you referring to the circuit supplying power to the control panel or the initiation/notification branch circuits controlled by the fire alarm system? The ampacity of the fire alarm control panel would determine the circuit size of the branch circuit supplying power to the control panel and the terminal on the control panel and fire alarm device would detrmine the size of conductor that it will accept. Most fire alarm control panels would require a minimum 15 amp circuit. The minimum conductor size allowed per the NEC would be 14 AWG. 22 AWG. is the smallest conductor that most control panels and device terminals will accept. These are considered Power Limited circuits.


In terms of fire fighting what does the acronym FIP mean?

fIRE iNDICATOR pANEL


Are Westinghouse breakers compatible in Siemens panel?

Yes they are. I would only use them as a temporary measure until obtaining the correct Siemens breaker. There is a part of the electrical code about modifying electrical equipment which this could be construed as. If the panel certification is lost and the panel faults and a fire occurs, your insurance company might not cover the losses occurring from the fire.


How can you stop electrical fires?

If you have an electrical fire, it would be a good idea to turn off the electricity if you have access to the fuse box or circuit breaker panel; other than that, use a fire extinguisher if the fire is not too large. If the fire is large, then only the fire department can deal with it.


Can fire alarm sub panel power supply tap from main fire alarm panel?

Yes, as long as there is enough typical/backup/standby power for both.


What would cause your car to start just fine and then just shut off and i have no panel or gauge lights?

Sounds like a bad ignition switch.


What material would you use to make a tool for roasting marshmallows over a fire?

a metal stick with a handle will do just fine!


Fire detection remote control panel?

An additional panel which is connected to the excisting main control panel, displaying all the information that the main panel displays in another location. For example, in an offcie building, you may have the main control panel at the main entrance/exit while you have the remote panel in a security/fire office somewhere else in the building so that the cause of the fire alarm can be easily identified without having to go across one building.


What is the difference between 'Class A' fire alarm vs 'Class B' fire alarm wiring?

In class A wiring, 2 wires start from alarm control panel terminal, run through fire sensors / detectors and the same 2 wires run back into the alarm control panel and get connected as 2 more wires thus there would be 4 wires at the panel totally. This would help the control panel monitor all the sensors / detectors even if a loop wire breaks in the middle. In Class B wiring, the control panel is just connected to 2 wires. These 2 wires run through fire sensors / detectors and terminate at end of line resistor. Thus if any wire breaks in between the sensors that are connected to control panel end of wire would only be monitored. The broken wire side of sensors won't be monitored