Apparent power is the vector sum of a load's true power and its reactive power. If you draw a 'power diagram', the phase angle will be the angle between the true power and the apparent power. If true power is fixed, then increasing the phase angle will result in a greater value of apparent power.
No way. The Power only manifests itself in the true blood. If you're not of true blood you can't be a conduit of the Power
Power factor is truepower divide by apparent power.
It's actually cos phi, where the Greek letter, 'phi', is the symbol for phase angle -the angle by which a load current lags or leads the supply current in an a.c. system (the Greek letter, 'theta', is used for the displacement of instantaneous values of current or voltage from the origin of a sine wave).The reason why power factor is a cosine requires you to understand the relationship between apparent power, true power, and reactive power. Apparent power is the vector sum of true power and reactive power, and can be represented, graphically, by the so-called 'power triangle'. In the power triangle, true power lies along the horizontal axis, reactive power lies along the perpendicular axis, and the apparent power forms the hypotenuse, and the angle between true power and apparent power represents the phase angle. By definition, power factor is the ratio between true power and apparent power, and this ratio corresponds to the cosine of the phase angle.From this, we can conclude that true power = apparent power x cos phi, where 'cos phi' is the 'factor' by which we must multiply apparent power to determine true power -i.e. the 'power factor'.
Use a wattmeter, as it only reads 'real power' of your load. Use an ammeter and a voltmeter, and the product of the two readings will give you 'apparent power' of your load. Since apparent power is the vector sum of real power and reactive power, use the following equation to find the reactive power of your load: (reactive power)2 = (apparent power)2 - (real power)2
Real Power: The actual power in Watts or K-Watts in AC or DC Circuits Apparent power: The Power in Inductive or Capacitive Circuits have Phase Lag & Lead measured in Volt Amperes VA or Kilo Volt Amperes KVA
The ratio of apparent power to true power is called 'admittance', expressed in siemens. Admittance is the inverse of impedance.
The Power of the True Love Knot was created in 1968.
Apparent power is the vector sum of a load's true power and its reactive power. If you draw a 'power diagram', the phase angle will be the angle between the true power and the apparent power. If true power is fixed, then increasing the phase angle will result in a greater value of apparent power.
true
True
to put out the power fector you have to divided apparent power with true power.AnswerYou can determine the true power of any load using a wattmeter. To find the apparent power, you use a voltmeter to measure the supply voltage and an ammeter to measure the load current, and multiply the two readings together.If you then want to go on to find the power factor, then you divide the true power by the apparent power. If you want to find the reactive power you use the following equation:(reactive power)2 = (true power)2 x (apparent power)2