The coarse adjustment knob is only used with the low-power objective lens (usually 4x) because all the other ones are too long and the coarse adjustment knob may bring the slide up too qucikly, therefore it might break the slide or crush the specimen being observed.
When using the medium (10x) and high (40x) power objective lens, it is best to use the fine adjustment knob to focus on the details instead.
The big knob on a microscope is typically called the coarse focus knob. This knob is used to move the objective lenses closer to or further away from the specimen, allowing for rough adjustment of the focus.
First of all, one should never call it high power, it is morecommonly called the "high objective", yet that is not what this question is asking. To answer the question: You use the fine adjustment knob. This knob should be located near the coarse adjustment knob, on the opposite side of the microscope (at the same height as the coarse adjustment knob), or even as a separate knob protruding from the coarse adjustment knob. The fine adjustment knob is smaller in size. You should never, ever use the coarse adjustment knob under the high objective, you could scratch the microscope slide, cover slip, high objective lens, or in a worst case scenario break the high objective lens.
Turning the coarse objective knob downward can cause the objective lens to come in contact with the slide, potentially damaging both the lens and the slide. It is best to always start with the coarse knob in the upward position to prevent any accidental collisions.
We avoid using the coarse focus knob with the 40x lens because it can lead to a high risk of crashing the lens into the slide, potentially damaging both the slide and the objective lens. The coarse focus knob moves the stage significantly, which is suitable for lower magnifications, but at high power, even small movements can cause contact. Instead, the fine focus knob should be used to make precise adjustments for clear imaging.
Nothing will happen because the coarse adjustment knob controls the position of the stage of the microscope, which is used to focus the specimen. This adjustment is independent of the choice of objective lens.
The coarse focus knob should be used with low power objective lenses, typically 4x and 10x, to bring the specimen into general focus quickly. This knob makes larger adjustments to the focus position.
The coarse focus knob should be used with the low power objective but not with the high power objective. The point of using the coarse focus knob is to bring the specimen into general focus before fine-tuning with the high power objective, which requires more precise adjustments.
The big knob on a microscope is typically called the coarse focus knob. This knob is used to move the objective lenses closer to or further away from the specimen, allowing for rough adjustment of the focus.
The fine adjustment knob is used with the power objective on the microscope. Since the objective is already at the highest objective possible for that microscope, using the coarse adjustment knob would focus to much on the object making the details harder to read. Using the fine adjustment knob, you are able to see the fine details within the object or organism you are studying. The higher the power, the finer the knob and the lower the objective, the coarser the knob and objective.
When using the scanner and low objective on a microscope, you should use the coarse focus knob to bring the specimen into approximate focus and then use the fine focus knob to achieve a sharp image. Adjusting the height of the stage may also be necessary to fine-tune the focus.
You would use the coarse adjustment knob to quickly bring the specimen into view, and then the fine adjustment knob to focus on the details of the specimen.
The coarse focus knob is used to quickly adjust the distance between the objective lens and the specimen on a microscope to bring it into approximate focus. It is mainly used for initial focusing before using the fine focus knob for precise focusing.
You MUST use the coarse focus knob.
The coarse focus knob is responsible for moving the body tube and objective up and down to help focus on the specimen. This knob allows for larger, quicker adjustments to the focus compared to the fine focus knob.
First of all, one should never call it high power, it is morecommonly called the "high objective", yet that is not what this question is asking. To answer the question: You use the fine adjustment knob. This knob should be located near the coarse adjustment knob, on the opposite side of the microscope (at the same height as the coarse adjustment knob), or even as a separate knob protruding from the coarse adjustment knob. The fine adjustment knob is smaller in size. You should never, ever use the coarse adjustment knob under the high objective, you could scratch the microscope slide, cover slip, high objective lens, or in a worst case scenario break the high objective lens.
Turning the fine adjustment knob moves the objective lenses the smallest vertical distance with precision, while turning the coarse adjustment knob moves the lenses the greatest vertical distance quickly.
Turning the coarse objective knob downward can cause the objective lens to come in contact with the slide, potentially damaging both the lens and the slide. It is best to always start with the coarse knob in the upward position to prevent any accidental collisions.