common phase
There are no three phase 120 volt systems.
Voltage phase to phase in a 380V 3-phase system refers to the voltage measured between any two of the three live conductors in the system. In a balanced 3-phase system, the phase to phase voltage is equal to the line voltage, which is 380V in this case. This voltage is commonly used in industrial and commercial applications to power heavy machinery and equipment. It is important to note that the phase to phase voltage is higher than the phase to neutral voltage in a 3-phase system.
5000 volt
The voltage you are referring to is a 'line-to-line' voltage ('line voltage'), as there is no such thing as a 'phase-to-phase' voltage.480 volts. In real life, the voltage will vary slightly by up to 3% (14 V) on a properly sized circuit. Line to neutral will measure 277 volts, plus or minus 3%.
Check for a blown fuse in one of the phase legs.
220 volt single phase from 480 volt 3 phase that one wire taken one phase and second wire connected in earth point. we get 220 v The above answer is incorrect, one phase from a three phase 480 volt system will give you 277 volts to ground. You must use a transformer to get the voltage you need.
No a 208 volt outlet does not need a neutral. 208 volts is the line voltage between any two legs of a three phase 208 volt system.
no
Question is incorrect. in a 240 Volt single phase circuit, how can you have A phase and B phase?
Usually yes. A typical 480 volt panel is a 3 phase panel with 480 volts line-to-line and 277 volts line-to-neutral. However, I did once see a panel that was 480 volts, 3 phase, but because it served only motors it did not have a neutral. (a 3 phase motor doesn't use a neutral.) Similarly, if a panel uses only 2 legs of a 3 phase 480 volt system, which would be called single phase, it would not require a neutral if it only feeds 480 volt single phase loads. But I find the idea of no neutral to be extremely unusual and in my one personal experience, I blamed it on the age of the system. In 16 years of commercial and industrial construction I have never installed a 3 phase panel without a neutral and all my work is designed by engineers.
is there a minimum distance between 480 volt phases. ANOTHER ANSWERThere is no such thing as a 'phase-to-phase' voltage. The correct term is 'line-to-line', which is why that voltage is called a 'line voltage'. The distance between these line conductors depends on the value of the line voltage; the greater the line voltage, the greater this distance must be to prevent any flashover. These distances are specified in the utility company's standards or regulations.
Use a transformer.