Yes up to certain rating and application a motor can be started on DOL. Beyond a rating different methods need to be used to limit the starting current.

User Avatar

Wiki User

11y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Why DOL starter using to start motor?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Engineering

What is Direct online Starters?

A direct on line starter, often abbreviated DOL starter, is a widely-used starting method of electric motors. The term is used in electrical engineering and associated with electric motors. There are many types of motor starters, the simplest of which is the DOL starter. A motor starter is an electrical/electronic circuit composed of electro-mechanical and electronic devices which are employed to start and stop an electric motor. Regardless of the motor type (AC or DC), the types of starters differ depending on the method of starting the motor. A DOL starter connects the motor terminals directly to the power supply. Hence, the motor is subjected to the full voltage of the power supply. Consequently, high starting current flows through the motor. This type of starting is suitable for small motors below 5 hp (3.75 kW). Reduced-voltage starters are employed with motors above 5 hp. Although DOL motor starters are available for motors less than 150 kW on 400 V and for motors less than 1 MW on 6.6 kV. Supply reliability and reserve power generation dictates the use of reduced voltage or not. A very well-known motor starter is the DOL Starter of a 3-Phase Squirrel-Cage Motor. This starter is sometimes used to start water pumps, compressors, fans and conveyor belts. With a 400V, 50 Hz, 3-phase supply, the power circuit connects the motor to 400V. Consequently, the starting current may reach 3-8 times the normal current. The control circuit is typically run at 24V with the aid of a 400V/24V transformer


Why induction motor should not start by direct switching?

because IM draws 4 to 5 times the rated current when it is connected to the supply directly in order to start the IM smoothly we need starters 1.star delta starter 2.auto transformer starter DOL starter for direct starting for smaller capacity IM (upto 1HP) Note:IM means Induction motor


What is the difference between a star-delta starter and a DOL starter?

At least two types of 3-phase electric motor starter are available: Direct-On-Line (DOL) and Star-Delta.For more information about how they work, and the differences between them, see the answers to the Related Questions shown below.


How does a dol starter work?

A Direct-On-Line (DOL) starter is an electronic 3-phase motor-control system which offers soft starts in DELTA configuration. DOL starters are now replacing the use of manual or semi-automatic "star-delta" starters.In this way of starting a 3-phase motor, full line voltages are applied to the motor through relays and contactors. The DOL is nowadays the most common type of 3-phase motor starter used.It has a "closing circuit" and an "opening circuit". The closing circuit is for applying the service lines to the motor and the opening - or "tripping" - circuit protects the motor by cutting-off (or "tripping") power to the motor from the service lines if there is any overload condition, a single phasing fault, etc.For more information please see the answers to the Related Questions shown below.


Direct online starter circuit diagram?

There is a link below for the DOL starter circuit.

Related questions

Can DOL starter use for 50kw motor?

The answer is yes. I had seen 110kW pump start on DOL starter


How do you work Dol starter?

A DOL or direct on line starter works by connecting the motor terminals directly to the power supply when they are energized. A DOL starter is the simplest type of motor starter.


Soft starter for a dc motor?

It is an advanced power electronic device to start the motor with a very smooth starting curve. It is next generation starter compared to DOL or star Delta starter


Why DOL starter is used in industries in-spite it has disadvantages?

DOL starters are used in industries in-spite of its disadvantages because it is the simplest form of a motor starter. A DOL starter consists of a MCCB or circuit breaker, contactor, and an overload relay that is used for protection.


What is meant by DOL direct on line?

DOL or Direct On Line is used when referring to induction motor starters. The simplest and most common type of motor starter is the Direct On Line. Some examples where a DOL starter would be used can include water pumps, compressors, conveyor belts and fans. A DOL starter can only be used if the sudden inrush of the motor starting does not cause voltage to drop excessively in the supply circuit.


Why you use DOL starter in starting of motor?

because of starting current of induction motor is very high and it damages the insulation of motor


Is DOL starter is sufficient for 10HP 2880 RPM motor?

If the application is high starting torque, then go for star delta or soft starters. If not DOL will do.


Why we used starter in motor?

There has to be device or a mechanism to start and stop a motor. hence a starter is needed. There are many different ways to start a motor. Considering AC Motor - It could be DOL, Star-Delta starters, which are age old and conventional. Star Delta starter starter is for higher rating motors, example over 7.5 kw, depending upon type of load. There are more advanced starters like Soft starters and Drives also.


Why starter used in motor?

There has to be device or a mechanism to start and stop a motor. hence a starter is needed. There are many different ways to start a motor. Considering AC Motor - It could be DOL, Star-Delta starters, which are age old and conventional. Star Delta starter starter is for higher rating motors, example over 7.5 kw, depending upon type of load. There are more advanced starters like Soft starters and Drives also.


What is the purpose of dol starter in three phase motor?

Three phase motors are controlled by a device called a starter. The starter allows the motor's supply voltage to be applied to and removed from the motor. These types of starters coil's can be controlled with usually a lower voltage that can be remotely controlled.


What is Direct online Starters?

A direct on line starter, often abbreviated DOL starter, is a widely-used starting method of electric motors. The term is used in electrical engineering and associated with electric motors. There are many types of motor starters, the simplest of which is the DOL starter. A motor starter is an electrical/electronic circuit composed of electro-mechanical and electronic devices which are employed to start and stop an electric motor. Regardless of the motor type (AC or DC), the types of starters differ depending on the method of starting the motor. A DOL starter connects the motor terminals directly to the power supply. Hence, the motor is subjected to the full voltage of the power supply. Consequently, high starting current flows through the motor. This type of starting is suitable for small motors below 5 hp (3.75 kW). Reduced-voltage starters are employed with motors above 5 hp. Although DOL motor starters are available for motors less than 150 kW on 400 V and for motors less than 1 MW on 6.6 kV. Supply reliability and reserve power generation dictates the use of reduced voltage or not. A very well-known motor starter is the DOL Starter of a 3-Phase Squirrel-Cage Motor. This starter is sometimes used to start water pumps, compressors, fans and conveyor belts. With a 400V, 50 Hz, 3-phase supply, the power circuit connects the motor to 400V. Consequently, the starting current may reach 3-8 times the normal current. The control circuit is typically run at 24V with the aid of a 400V/24V transformer


Why induction motor should not start by direct switching?

because IM draws 4 to 5 times the rated current when it is connected to the supply directly in order to start the IM smoothly we need starters 1.star delta starter 2.auto transformer starter DOL starter for direct starting for smaller capacity IM (upto 1HP) Note:IM means Induction motor