answersLogoWhite

0

Micrometer is having a ratchet to rotate which is pre-loaded to get standard thrust while measurement, whereas in the case of a vernier the accuracy of measurement depend on the pressure each individual applying while the measurement.

User Avatar

Wiki User

9y ago

What else can I help you with?

Continue Learning about Engineering

What type of micrometer is easiest to read?

A digital micrometer is the easiest to read as it displays the exact reading on a screen.


HOW TO USE A screw-thread micrometer?

First calibrate the micrometer by dialing the spindle to zero and adjusting the anvil until it is flush against the spindle. Measure the screw until the ratchet begins to click and take the first reading. This reading can then be compared to a machining book to verify the pitch diameter.


How does one avoid lifting of the bridge of the depth micrometer?

To avoid lifting of the bridge of the depth micrometer, make sure that the spindle is correctly positioned before taking a reading. The spindle should be parallel to the base of the depth micrometer and should be positioned directly over the object being measured. Make sure that the object being measured is firmly supported and that the work surface is free of debris that may interfere with the depth micrometer’s operation. Before taking a reading, check that the anvil and spindle are perfectly aligned with each other. Avoid pressing down on the depth micrometer too hard as this can cause the bridge to lift. Always use the correct size micrometer for the job and the correct size anvil for the object being measured. If the bridge does start to lift, stop and correct the problem before taking any further readings. Before taking a reading, always make sure that the depth micrometer is properly zeroed. When using a depth micrometer, always keep your hand away from the spindle and anvil. Make sure that the depth micrometer is properly maintained and stored in a dry, clean environment. Lastly, always use the depth micrometer with care and caution to avoid any damage or inaccuracy.


On a good compressor using an ohm meter you should get a positive reading from common?

Well, isn't that a happy little question! When testing a compressor with an ohm meter, you should get a positive reading from the common terminal. This indicates that the winding inside the compressor is intact and functioning properly. Just remember to always refer to the manufacturer's guidelines for specific readings and instructions.


What will happen to DC signal if positive probe connected to negative terminal and negative probe connected to positive of DC supply oscilloscope?

If the positive probe of the oscilloscope is connected to the negative terminal and the negative probe is connected to the positive terminal of a DC supply, the oscilloscope will display an inverted signal. This means that the voltage reading will be negative, effectively showing the opposite polarity of the actual DC voltage. The magnitude of the reading will remain the same, but the trace on the oscilloscope will appear flipped around the zero voltage line.

Related Questions

What is the 'zero error' in vernier calipers and micrometer screw gauge?

In vernier calipers, zero error is when the jaws of the caliper do not close properly when they are in contact without measuring anything, resulting in a measurement that is not accurate. In a micrometer screw gauge, zero error occurs when the flat end of the spindle does not perfectly align with the reference line on the sleeve at zero reading, leading to inaccurate measurements.


What type of micrometer is easiest to read?

A digital micrometer is the easiest to read as it displays the exact reading on a screen.


What is the zero reading of 50-75mm outside micrometer?

The zero reading of a 50-75mm outside micrometer is the measurement displayed when the micrometer's anvil and spindle are in contact without any additional force applied. Ideally, this reading should be exactly zero, indicating that the micrometer is calibrated correctly. Any deviation from zero suggests the micrometer may need adjustment or recalibration to ensure accurate measurements. Regular checks against a standard gauge can help maintain the micrometer's accuracy.


What is positive zero error in a micrometer?

This is the measurement recorded when, in fact, it should be 0. It is the measurement when there is nothing to measure but the reading is not exactly 0 because the calibration has gone off.


When reading a small-hole gauge how is the micrometer reading taken in relation to the split in the ball on the split or 90 degrees to it?

When reading a small-hole gauge, the micrometer reading is taken at the point where the split in the ball aligns horizontally at 90 degrees. This allows for an accurate measurement of the diameter of the hole based on where the micrometer lines up with the scale on the gauge.


To what decimal can you estimate the reading on a micrometer?

My micrometer reads out to ten-thousandths of an inch.EX: .2501".This is 250 thousandths plus 1-ten thousandths of an inch.I never guesstimate a reading...Hope this helps


How tight is the thimble turned when testing zero on a micrometer?

All you need to do is make contact. Tightening will give you a false reading and eventually damage the micrometer.


How you remove zero error from micrometer screw gauge?

To remove zero error from a micrometer screw gauge, first, close the micrometer completely and check the reading on the scale. If it does not read zero, note the error value. To correct for this error in future measurements, simply add or subtract the zero error value from your measurements, depending on whether it is a positive or negative error. Alternatively, you can adjust the micrometer's anvil or spindle if it has a calibration feature to bring it back to zero.


What is the instrument used to measure diameter of testtube?

Calipers measure the internal or external dimensions of something.


What is the expected Error using micrometer?

the spindle must be tighten to avoid slightly changes on the reading


How do you calculate accuracy for micrometer?

To calculate the accuracy of a micrometer, you first measure a known standard (like a gauge block) using the micrometer and record the reading. Then, compare this reading to the actual known value of the standard. The accuracy can be determined by calculating the difference between the measured value and the known value, often expressed as a percentage of the known value. Additionally, consider the micrometer's least count and any calibration errors to ensure a comprehensive assessment of accuracy.


HOW TO USE A micrometer?

First calibrate the micrometer by dialing the spindle to zero and adjusting the anvil until it is flush against the spindle. Measure the screw until the ratchet begins to click and take the first reading. This reading can then be compared to a machining book to verify the pitch diameter.