Because inverters do not produce a pure sinewave AC and you did not use a True RMS digital meter to measure the voltage.
Meters that are not True RMS actually measure the average, then display the value on a scale that assumes the input is a pure sinewave showing what the RMS would be for that average. For waveforms significantly different from sinewaves (as the inverter produces) that displayed value can be seriously wrong.