It works just fine. If you have one that is malfunctioning, there are two possibilities:
1...It is mechanically jammed.
2...It has a shorted turn on one of it's windings.
a three phase motor will work
A connection of a contactor to three phase motor.
yes. that's how they work!
A three phase motor will not operate on single phase. The motor will run on two phases but will not start. Motors running on just two phases is called single phasing. The line current of the two legs will go high and it is this factor that the motor controller uses to trip the contactor to open the circuit and isolate the motor from the power source.
The winding design of the motor will not economically allow this to work. You would have to drive a 3 phase generator to supply it.
Your question is a little like asking, 'How long is a piece of string?'! Do the two motors have the same power rating, or are they different?The rate at which energy is used by any machine is defined by its power rating. If the power ratings of two different machines are the same, then both machines use energy at the same rate. So if a single-phase motor has the same power rating as a three-phase motor, then they will both use exactly the same amount of energy over a given period of time.So, if a single-phase motor has a greater power rating than a three-phase motor, then the single-phase motor will the greater amount of energy in a given period. On the other hand, if a three-phase motor has a greater power rating than a single-phase motor, then the three-phase motor will the greater amount of energy in a given period.
if it doesnt work on 1 and 2 it could be a blower motor resistor but if it doesnt work at all check the fuses, relay and check voltage if it reads 12 v replace the motor
The motor cannot be altered to work on single phase power. You will either have to put in a new single phase motor or use a phase convertor box. Do a google search for phase convertor - you will find plenty.
Single phase to three phaseThe physical internal windings between single phase and three phase motors makes this an impossibility That being said money can make anything happen. Depending on the amount of money you want to spend to make this happen there is a device on the market called a VFD ( Variable Frequency Drive). On the three phase input terminals you apply your single phase voltage. On the output terminals you connect your three phase motor. When run in this configuration there is an internal switch that has to be changed to let the VFD know that it should be looking for only two lines on the input to be hot. Other wise the VFD thinks that there is a line loss on the three phase input terminals and the unit will not start.Some 3 phase motor speed controllers can be run off a single phase supply, this caused us a problem at work when a new speed control was fitted to some laundry equipment, as we then had to rewire the supply to bring in a nuetral, so i suggest a speed controller is probably the solution.
No. A three-phase ballast requires three-phase power
yes the motor will rotate but less then the rated speed and more heat will be desipated
Any business, such as a factory, or any home needing a 3-phase supply for some equipment would usually get that supply by having it installed by their local electric power utility company.For a very small 3-phase motor, solid state power inverter units are available nowadays which can be powered from household 1-phase supply.If you want to know how to convert a 1-phase to a 3-phase supply for high power applications it can be done using a motor/alternator set or a solid state inverter unit but to use these safely requires specialized equipment and electrical engineering knowledge. The full answer is too complicated to explain here.Depending on the amount of money you want to spend to make this happen there is a device on the market called a VFD ( Variable Frequency Drive). On the three phase input terminals you apply your single phase voltage. On the output terminals you connect your three phase motor. When run in this configuration there is an internal switch that has to be changed to let the VFD know that it should be looking for only two lines on the input to be hot. Other wise the VFD thinks that there is a line loss on the three phase input terminals and the unit will not start.Before you do any work yourself,on electrical circuits, equipment or appliances,always use a test meter to ensure the circuit is, in fact, de-energizedIF YOU ARE NOT REALLY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.