Any business, such as a factory, or any home needing a 3-phase supply for some equipment would usually get that supply by having it installed by their local electric power utility company.
For a very small 3-phase motor, solid state power inverter units are available nowadays which can be powered from household 1-phase supply.
If you want to know how to convert a 1-phase to a 3-phase supply for high power applications it can be done using a motor/alternator set or a solid state inverter unit but to use these safely requires specialized equipment and electrical engineering knowledge. The full answer is too complicated to explain here.
Depending on the amount of money you want to spend to make this happen there is a device on the market called a VFD ( Variable Frequency Drive). On the three phase input terminals you apply your single phase voltage. On the output terminals you connect your three phase motor. When run in this configuration there is an internal switch that has to be changed to let the VFD know that it should be looking for only two lines on the input to be hot. Other wise the VFD thinks that there is a line loss on the three phase input terminals and the unit will not start.
Before you do any work yourself,
on electrical circuits, equipment or appliances,
always use a test meter to ensure the circuit is, in fact, de-energized
IF YOU ARE NOT REALLY SURE YOU CAN DO THIS JOB
SAFELY AND COMPETENTLY
REFER THIS WORK TO QUALIFIED PROFESSIONALS.
No, a single-phase supply cannot be directly used in a three-phase system. The voltages and phases are different, so additional equipment such as a phase converter or transformer would be needed to convert the single-phase supply to match the requirements of the three-phase system.
ENERGY
The Single and Three phase refer to Alternating Current electrical power supply outlet system and the corresponding equipment requirements. The single phase system is generally used thepower requirements are low or moderate as for household applications , while the Three phase supply system is used for High power industrial applications. Thenumbers of phases refer to Alternating Current Supply lines which are delivering the power or the sytem requirement of the equipment for operation. Thus a single phase supply cannot operate a three phase equipment or vice versa. However a ThreePhase supply can be used individually as Three different Single Phase supply systems In case of Three Phase systems the electrical supply waveforms are such that at any given instant there is a 120 degree phase difference between any two supply lines , which also results in higher magnitude of supply voltage than the corresponding single phase supply. Now refering to the inverter which is nothing but a device to convert the electrical supply from one source or magnitude ( typically DC from a Battery Bank ) to the required form and Magnitude. Thus it simply generates the equivalent electrical supply either as Singleor Three Phase , which ideally will be the same as available available from the wall outlet
The standard nominal voltage in Canada for a single-phase residential supply is 240/120-V split-phase supply.
For a three-phase, four-wire, system, single-phase loads can be connected between any pair of line conductors. For a three-phase, four-wire, system, single-phase loads can be connected between any pair of line conductors, or between any line conductor and the neutral conductor. The choice depends on the voltage requirements of the load.
The power is generated in the form of three-phase in aircraft, and this sytem has no problem in feeding single phase loads. To conserve mass in tansformers and motors the supply works at 400 Hz.
Yes of course!! 10 kva electrical power is 10 kva electrical power either it would be three phase or single phase. But other factors i.e. current, voltage changes accordingly. Actually this question is quit confusable. Because in 3phase system, if each phase gives 10kva power (single phase power = 10 kva) then 3 phase power will be 10 X 3 = 30 Kva If we go leteratualy towasrds the question, then the asnwer will be - No. becasue 10 kva supply to 3 phase load will be 3phase supply(i.e440V) & 10kva supply to single phase load will be single supply (i.e 250V).
Houses generally run on single phase power. It would not make sense to convert single phase to three phase to run a house. Please restate the question.
It is possible to run a DC motor on a 3-phase supply using a full-wave rectifier if the voltage is right.
Answer for USA, Canada and countries running a 60 Hz power supply service. Yes, but you will need to change the wire from a 2 wire cable to a 3 wire cable. This allows the neutral to be brought out to the load.
A single handle uses the same 3 holes as the double handle
A single-phase supply is obtained between any two line conductors or between a line and neutral conductor of a three-phase supply. To obtain a three-phase supply from a single-phase source is far more difficult, and requires additional equipment.
There is no 'total voltage' in a three-phase system. There are three line voltages and three phase voltages.
415V 3 phase is the line to line voltage. The line to neutral of this supply is 230V single phase. Therefore you use one of the phases and the neutral.
No, a single-phase supply cannot be directly used in a three-phase system. The voltages and phases are different, so additional equipment such as a phase converter or transformer would be needed to convert the single-phase supply to match the requirements of the three-phase system.
Yes if not provided with enough and right shielding as required for electronic device.
usually they say its possible 2 convert a 2phase supply to 3 phase.if its so then how?