Loose connection? Blower motor going bad-windings opening when they get hot loose fuse holder

001
๐Ÿฆƒ
0
๐Ÿคจ
0
๐Ÿ˜ฎ
0
๐Ÿ˜‚
0

Related Questions


Your inside blower motor is most likely bad and if not then check the capacitors and the wiring, but I would go with the blower.....


Possibly. A bad blower motor resistor would cause the blower motor to either not function or function only on one speed (usually high speed). The air conditioning system is probably set up such that if the blower isn't functioning at all, the air conditioner won't function. Otherwise the air conditioner would overheat.



If you are referring to the blower motor speed, and only the highest setting works, then the problem is a bad Blower Motor Resistor Pack.




Yes. It is located behind the glove box in the A/C housing between the blower motor and the evaporator.


Start with: Possible control, blend door or blend door actuator, low pressure switch, leak in system.



The blower motor is probably busted, or the blower speed switch could be busted as well, if that isn't it could be a fuse for the blower motor I would check that first and save your self alot of time and money.


You don't have to. but you'll probably regret it if you don't. Dust will build up inside the blower and the ventilation pipes. Also, the house will be a lot dustier than it would be otherwise.


Blower is about to die. I had same symptoms. Blower would not come on so I would run over bumps then it would engage. Replace blower no problems since.


Defective blower motor. Although I do not know if this is the problem, I have seen this on other vehicles. Check into the blower motor resistor. RockAuto.com has them with great pictures so you know exactly what you are looking for. They are generally located close to the blower under the dash. Very easy fix just a couple of screws. Cheaper and easier than replacing the blower motor.


Well you could have a lose connection or bad resistor or bad switch and it takes power away from the engine because the ac compressor puts a load on the engine when it's running


Blown fuse? Bad blower motor? Bad blower motor resistor? Bad blower motor switch?


no just water but i don't believe that conditioner would harm it


the solute in hair conditioner would be the moisters and the sovent would be the water that you start off with to make the conditioner. I hope that helps:), i askeed my teacher about that, and that is the answer that she told me.


The blower may simply have burned out. If the blower is out then the heater probably still works.


Defective blower motor or blower motor resistor pack.


If you only have high speed I would blame the blower speed resister. If you have no speeds and the fuse is good, I would blame the blower motor or the switch.


Pacitan is a regency in Indonesia on the continent of Asia.


Check the fuses first and the blower relay.


i would like to know where the pvc valve is and how to change it on my 1990 olds 98 regency 3.8.


Could be, a blown fuse, a bad blower motor, a burned out blower motor speed resistor, a bad blower motor switch,