because current entering ct's of High Side is not equal to low side ct's output current

User Avatar

Wiki User

16y ago

What else can I help you with?

Related Questions

Which types of relay is use in power transformer?

A 'power transformer' is a category of transformer used within electricity transmission and primary distribution systems. Relays are widely used with power transformers to provide various types of protection that will act to disconnect the transformer in the event of a fault. Examples of these relays include Buchholz relays, earth-fault relays, and differential relays. Relays are also used to operate a power transformer's automatic tap-changing mechanism in order to compensate for changes in load.


How is restricted earth fault called so how is it restricted?

A Restricted Earth Fault (REF) refers to a method of fault protection that is applied to electrical system units, such as transformers or generators, that is more sensitive than the method known as Differential Protection (DP).An REF relay works by measuring the actual current flowing to earth from the frame of the unit. If that current exceeds a certain preset maximum value of milliamps (mA) then the relay will trip to cut off the power supply to the unit.REF protection is applied on transformers in order to detect ground faults on a given winding more sensitively than when only using differential protection.Differential Protection is commonly used to protect the windings of a transformer by comparing the current in the power supply's neutral wire with the current in the phase wire. If the currents are equal then the DP Relay will not operate. If there is a current imbalance then the DP Relay operates.REF and DP protection devices operate in similar ways to a GFCI or RCD device, which combines both REF and DP functions inside the one single device.For more information about GFCIs and RCDs, please see the answer to the Related Question shown below.


What is an earth fault relay?

An earth fault relay is a relay that is activated by a fault current that flows from the power line to the earth. Earth fault relays are found in power distribution systems.


What is through fault?

A fault occurs by 2 plates sliding along each other and then breaking.


100 amps mccb trip when charged it is connected to small power transformer?

what is the fault in the transformer, it trips when it is charged.it is charged through the 100 amps MCCB.


What is restricted earth fault protection and how is it provided?

A Restricted Earth Fault (REF) means an earth fault from a restricted/localized zone of a circuit. The term "REF protection method " means not to sense any earth faults outside this restricted zone. REF is a type of "unit protection" applied to transformers or generators and is more sensitive than the method known as differential protection. An REF relay works by measuring the actual current flowing to earth from the frame of the unit. If that current exceeds a certain preset maximum value of milliAmps (mA) then the relay will trip to cut off the power supply to the unit. Differential protection can also be used to protect the windings of a transformer by comparing the current in the power supply's neutral wire with the current in the phase wire: if the currents are equal then the differential protection relay will not operate; if there is a current imbalance then the differential protection relay operates. However, REF protection is also applied to transformers in order to detect ground faults on a given winding much more sensitively than differential protection can do.


Is it possible for a power transformer to have an arc fault between the primary terminal and its metal enclosure?

Sure. No transformer is built to last forever. Aging and operations will weaken the insulation with time.


What is the application of current transformer?

Current transformers are found in power generation, electricity transmission & distribution, railways, industrial equipment, vessel propulsion, wind & solar renewables applications. In each application layer there are a number of sub-application levels for current transformers; for example, accurate measurement of power, protection of electrical plant, differential protection, restricted earth fault, isolated phase busduct, interposing, and summation.


What is neutral earth compensator?

For earth fault protection on the windings of a delta connected transformer. Used in MV distribution. An earth fault current return path is provided by connecting a Neutral Earthing Compensator (NEC) between the three phases of the power system and the earth system. This is done at the source of the supply. The NEC transformer winding has a Zig-zag configuration with no secondary winding. The impedance of the winding is high when there is no fault on the system resulting in only a small magnetising current in the transformer windings. The Zig-zag winding configuration results in a low impedance when an earth fault condition occurs. By inserting resistance between the neutral of the Zig-zag transformer and earth, the earth fault currents can be limited to any desired value. The resistance value and rating has been standardised to allow an earth fault current of 300 amp for 10 seconds, although some older installations may still operate at the old standard of 600 amps.


What is meant by the term ideal transformer?

ideal transformer is that which has no power losses.if any transformer transfer power to secondary without power loss then that call a ideal transformer


Is transformer an amplifier?

No. In an amplifier, Power Out > Power in. In a transformer Power Out ~= Power In (minus internal losses). An AC generator is more like an amplifier than a transformer.


What is the difference between power transformer and instrument transformer?

A power transformer is used to provide power (to your home, for example), an instrument transformer is used to measure voltage or current (for metering, for example).