Yes, but the motor's horsepower rating will not be reached.
Terminology gets misapplied but a 3-phase converter produces a 3 phase supply from a single phase supply. The only proviso is that generator, converter and motor are all suitably rated and compatible.
Shunt motors do operate on single phase AC. There are millions, if not billions of them worldwide running right now.Make certain your voltage supply is correct for your motor. Also, make certain you're providing the proper amperage. Make sure it's not a three phase motor. (three phase motors won't operate on single phase power.) If your supply voltage and amp supply is correct and the motor still doesn't run, you've got a bad motor.
Two scenarios are that the motor could be a three phase motor. These three phase motors are manufactured in smaller sizes. The other scenario is that the motor is a 208/220 volt single phase motor. It will operate on 208 volts by taking two legs of the three phase supply for its operation.
With no three phase power supply you can't use a three phase motor of any kind at all!
If the motor is connected to an ungrounded delta supply service there will be no effect on the operation of the motor. If the motor is connected to a wye system supply service and the B phase grounds out, the motor's overload protection would take the motor off line from the electrical supply.
Terminology gets misapplied but a 3-phase converter produces a 3 phase supply from a single phase supply. The only proviso is that generator, converter and motor are all suitably rated and compatible.
Shunt motors do operate on single phase AC. There are millions, if not billions of them worldwide running right now.Make certain your voltage supply is correct for your motor. Also, make certain you're providing the proper amperage. Make sure it's not a three phase motor. (three phase motors won't operate on single phase power.) If your supply voltage and amp supply is correct and the motor still doesn't run, you've got a bad motor.
The winding design of the motor will not economically allow this to work. You would have to drive a 3 phase generator to supply it.
Motors are rated in horsepower, not KW. A 750,000 watt motor, at 220 volt, would be a 1005 H.P. motor and about the size of a large pickup truck! I suspect you're asking about a 750 KW generator. You must not only supply the correct voltage and amperage to operate it, you must have a 3 phase power supply. Unless you're in a commercial bldg. you likely don't have 3 phase power and can't operate that generator.
We can convert a 3 phase ac motor into generator by changing phase sequence of the ac input cable of that motor
how reversing an ac single phase induction motor to wark as induction generator
A single phase supply can operate a three phase motor with a static converter. No a power supply of computer cannot be fed through the static converter.
You don't. A three phase motor will not start unless it is connected to a three phase supply.
No. That would be a single phase motor.
Two scenarios are that the motor could be a three phase motor. These three phase motors are manufactured in smaller sizes. The other scenario is that the motor is a 208/220 volt single phase motor. It will operate on 208 volts by taking two legs of the three phase supply for its operation.
You can get a buck / boost transformer which will step down the voltage. What will be important is phase supply.
With no three phase power supply you can't use a three phase motor of any kind at all!