depending on ambient temperature and humidity it is likely to freeze on cooling since there won't be enough heat exchange area or air flow to dissipate the 36,000 BTU of the 3 ton unit without dropping below freezing point of the water that will be condensed on the surfaces. On heating the temperature of the heat exchange coils will get too high the pressure will be too high and the outside unit will draw excessive power possibly trip a safety device. In short: it might but I sure would not risk it.
Rule of thumb is no more than 50 feet.
I have been told that if you are going to replace a 10 seer with a 13 seer, you have to change the coil on the inside unit to work with a 13 seer heap pump. In order to gain the extra energy efficiency yes you would need to replace the air handler as well.
An Amana heat pump works just like an air conditioner would work. When the temperature outside starts falling, the heat pump automatically turns on and by reversing the process of turning air cold, it heats the air instead, thus allowing you to keep your home warm.
An air conditioner if functioning as air warmer or air chiller can be called as a type of heat pump. If an air conditioner is working as an air de-humidifier then it no more a heat pump.
An air heat pump is used to heat and cool your home. It is like an air conditioner in the warmer months but then can also heat your home if the outside temperature is above freezing.
Yes, provided you have the properly matched Goodman evaporator coil in the air handler and the air handler is capable of delivering the correct amount of air flow (cfm) to support the new unit.
3.75
Rule of thumb is no more than 50 feet.
I have a4 ton air handler and a three and a half ton condenser 13 seer goodman heat pump will my seer change
if by how much you mean the heating or cooling capacity it is 60,000 BTU/hour
Yes. As long as the capacity, efficiency, and refrigerant are the same.
I have been told that if you are going to replace a 10 seer with a 13 seer, you have to change the coil on the inside unit to work with a 13 seer heap pump. In order to gain the extra energy efficiency yes you would need to replace the air handler as well.
A handler is simply a box that does nothing more than move air. This is most commonly used if you do not have a central heating system and you want to install central AC or a heat pump. The coil is installed in the box and the blower is then able to blow the air into the home.
air handler
An Amana heat pump works just like an air conditioner would work. When the temperature outside starts falling, the heat pump automatically turns on and by reversing the process of turning air cold, it heats the air instead, thus allowing you to keep your home warm.
Go to the mfr`s website and there should be a link there. Have the model and serial #`s for all pieces (condenser, air handler or furnace and the coil) handy when you do this.
An air conditioner if functioning as air warmer or air chiller can be called as a type of heat pump. If an air conditioner is working as an air de-humidifier then it no more a heat pump.