Q: Will a 3ton coil work on a 3.5ton condenser?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Do you have to have a 4 ton coil for a 4 ton ac unit?

The rating is technically a minimum. You could use a larger coil and have it work. But if its a Evaporator coil it will need to be matched on the far end with a similar or larger condenser coil. If the Condenser coil is larger it will probably just take a little more refrigerant.


88 Honda trx 350 has no spark coil is good what else could it be?

An 88 Honda trx 350 should have a set of points and a condenser under a side cover on the engine. If the points do not work properly of the condenser is bad then there will be no power going into the coil and there wont be a spark.


Can a 3 ton coil work with a 2 ton condenser?

Yes it will. Typically a coil is sized a 1/2 ton larger than the a/c out side for efficiency, but a whole ton bigger should still work


Can 3 ton a coil work with a 2 ton condenser?

Yes it will. Typically a coil is sized a 1/2 ton larger than the a/c out side for efficiency, but a whole ton bigger should still work


What size condenser do you need to match a 5ton 10 seer coil that is at least 9 years old?

A 5 ton 10 SEER condenser will do it, but you can no longer buy a 10 SEER condenser. Replacing the condenser and not matching it with the proper evaporator coil will nullify the SEER value stated on the new unit and your actual SEER and EER will be anyone`s guess so do not pay any attention to it. The coil is the least expensive component of the 3 and now would be the time to upgrade away from R 22 which is currently being phased out and will become very expensive in the near future. Something to consider if that 9 year old coil were to fail before the new condenser does or if you were to develop a troublesome leak. But if you are dead set against the coil replacement I suppose a 4.5 or 5 ton, depending on the climate where you live will work. Get the lowest SEER currently available (13) since it will mean nothing.


How does a coil work in a MGB?

how does a coil work in a MGB


Why does my Air conditioner not work during day and work good at night?

easy it is over heating for some reason your condenser is not removing the heata clean condenser with hoseb make sure fan is working or add extra fan to condenserc make sure coil is in good orderd you may have air in system remove charge evac and recharge.e recharge with pure propane r600a


How does the condenser focus knob work on a microscope work?

it helps look at objects up close


Will a 4 ton condenser unit work with a 3 ton furnace?

not very well. a 4 ton system needs about 1600 cfm to provide it's full capacity of cooling. a 3 ton furnace puts out about 1200 cfm. in addition, the evap coil typically attached to the furnace needs to match the tonnage of the outdoor unit. so, the evap coil must be 4 tons. If you currently have a 3 ton furnace and evap coil, the system will not work, and you will most likely ruin the compressor in the outdoor unit.


What size evaporator will work a 2 ton condenser?

1.5 ton evaporator


Why the vacuum is maintained in Steam condenser?

It is important to maintain a vacuum in a condenser if you want it to work well.


How does steam condenser work?

the work of the condensor is to condense the hot steam and change its state so that it can be used again in boiler