Where is the power coming from? Direct from the breaker panel or from another plug? Does that outlet have a wall switch? You pushed in the reset button on the new plug? You just have to back track and find the break in the line. Make sure the breaker is coming on.
If the test switch is faulty then there is no convenient way to determine if the GFCI is functioning, and technically, if the test switch is faulty, then as it is a part of the GFCI, the GFCI is faulty and should be replaced.
The pilot light in a GFCI is an indication that the receptacle is hot, maybe they should add a red pilot light to indicate that no power is coming out of the outlet and green when power is available.
If you have any question about the functionality of your GFCI, you should have it replaced. You can certainly verify that the GFCI is still functioning by using the test button, but the light gives added assurance that the circuit is functioning properly.
Connect the incoming power to the line side of the GFCi outlet. Now run another wire connected to the line side of the GFCI outlet from the GFCI outlet to the switches. Power one of the switches and use that switch to turn on the 2 lights. Run power from that switch to another switch and use that switch to send power to the fan. Mount both switches in a double pole switch box. If the light above the sink has an outlet on it then you will have to connect power going to that light on the load side of the GFCI outlet. If not then just connect it to the line side.
Receptacles are daisy chained so that one receptacle also powers others. A GFCI is often in the first receptacle so that a fault on any other connection/receptacle will be detected and cut off by that GFCI. Trip the GFCI. Then find all receptacles and appliances now without power. A fault can be in any one or due to a combination of many slightly defective appliances.
If the test switch is faulty then there is no convenient way to determine if the GFCI is functioning, and technically, if the test switch is faulty, then as it is a part of the GFCI, the GFCI is faulty and should be replaced.
Because something is wrong. Check for shorts and, if it is a GFCI, also check for ground faults and leakages. It is also possible, in the case of a GFCI, that an inappropriate load, such as a computer monitor or UPS, is connected. These devices pull transient power to ground and will trip a GFCI. Do not ignore the situation. The protective device is tripping for a reason.
No, except that you insert the wires into the holes on the back of the outlet. The power in connects to the LINE side of the outlet and power out connects to the LOAD side of the outlet. This is clearly marked on the back of the outlet. This will not only protect the outlet with the GFCI installed but all outlets receiving their power from that GFCI. If you do not want to protect the outlets receiving power from the outlet then connect that outgoing wire to the LINE side also. But know that only the outlet with the GFCI will be protected and all other outlets will not be GFCI protected.
Every time you trip the GFCI, the power to the device plugged into it will lose its supply voltage.
The pilot light in a GFCI is an indication that the receptacle is hot, maybe they should add a red pilot light to indicate that no power is coming out of the outlet and green when power is available.
If you have any question about the functionality of your GFCI, you should have it replaced. You can certainly verify that the GFCI is still functioning by using the test button, but the light gives added assurance that the circuit is functioning properly.
Connect the incoming power to the line side of the GFCi outlet. Now run another wire connected to the line side of the GFCI outlet from the GFCI outlet to the switches. Power one of the switches and use that switch to turn on the 2 lights. Run power from that switch to another switch and use that switch to send power to the fan. Mount both switches in a double pole switch box. If the light above the sink has an outlet on it then you will have to connect power going to that light on the load side of the GFCI outlet. If not then just connect it to the line side.
Connect incoming power to the line side of GFCI outlet and plug Jacuzzi into the outlet. Must be on a dedicated circuit. If it has a pump and heater then each one must be on dedicated GFCI protected circuit.
Ground wire is loose or disconnected somewhere in that circuit.
This indicates either you have an active ground fault or the GFCI is bad. To check this out turn off power at breaker and remove GFCI outlet from wall box. Determine if it is powering other non-GFCI outlets. (It will have both input and output wires. If there are output wires remove them and check the outlet again with power and see if it resets. If it does you have a ground fault down the line somewhere. If it still doesn't work you likely have a bad GFCI.
The meaning of the GFCI acronym stands for Ground Fault Circuit Interpreter. It is a special type of electrical outlet that prevents electrical power for safety reasons.
I assume you are hard wiring it and not plugging it in. The power coming into the GFCI outlet connects to the line side of the GFCI outlet. If you want the outdoor timer protected by the GFCI then connect the wire going to the timer to the load side of the outlet. If you do not want the timer protected then connect it to the line side. On the back of the GFCI if you look closely you will see Line & Load marked on the back.