Q: Can you replace 3 ton compressor to a 2.5 ton compressor?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What is the compressor amperage of a 3-ton system operating on 230v?

17amps


How many LRA in 1 ton air conditioner compressor?

How many lra 1ton 3 phase compressor


What value of capacitor for 2hp acu compressor?

acu compressor motor window type aircon 45 uf capacitor for 2.5 hp compressor 50 uf for 3 ton acu 60 uf for 1.5 hp compressor 35 uf


What is the cost to replace a 3 ton air conditioning unit?

53189


What happens if you install a 2 ton coil to a 3 ton air conditioning unit?

I'm not an air conditioning expert, but I would expect that the compressor will run a lot more than it needs to. A 2 ton coil will not cool as much air as a larger capacity 3 ton coil. Experts?


Can you install a 3.5 ton condenser on a 3 ton evaporator?

Installing a 3 1/2 ton condenser on a 3 tr evaporator will not function properly. There isn't enough evaporator coil surface area to absorb heat and vaporize refrigerant liquid for its return back to the condenser compressor. What can be done is a 3 ton condenser unit with a 3 1/2 evaporator coil.


Can you replace a 2 ton coil with a 3 ton coil?

Maybe. The coil is not matched to a 2 or 3 ton truck It is matched to the engine and igniton control system. So it may be the same part #.


Can you mix sizes of indoor and outdoor air conditioner units like a 4 ton compressor and a 3 ton condenser?

Absolutely NOT ! you will end up with more problems,and spend more redoing it because it doesn't work together.And besides a 4 ton compressor needs a 4 ton condensor.3 ton condensor will not have the surface area to cool the freon from a hot vapor to a cool liquid,that is needed for optimal performance in air handler,which is also rated for a 4 ton ,due to the coil size and the expansion valve size.


What is the cost to replace a 3 ton condensing unit?

just the condensing unit roughly 1500to2000


I have an outside 3 ton goodman condensor and my inside air handler is a trane 2.5 ton. can this cause my ac not to work efficiently?

If the coil in the air handler is 2.5 tons, yes. The system is mismatched and you may also experience compressor failures due to liquid refrigerant flooding back to the compressor due to the undersized evaporator coil.


What would be a ball park figure for replacing a heat pump compressor in a 2 yr old 3 ton Trane unit?

Last one I replaced was $8,700


Will a 4 ton condenser unit work with a 3 ton furnace?

not very well. a 4 ton system needs about 1600 cfm to provide it's full capacity of cooling. a 3 ton furnace puts out about 1200 cfm. in addition, the evap coil typically attached to the furnace needs to match the tonnage of the outdoor unit. so, the evap coil must be 4 tons. If you currently have a 3 ton furnace and evap coil, the system will not work, and you will most likely ruin the compressor in the outdoor unit.