Maybe.
The coil is not matched to a 2 or 3 ton truck
It is matched to the engine and igniton control system.
So it may be the same part #.
I'm not an air conditioning expert, but I would expect that the compressor will run a lot more than it needs to. A 2 ton coil will not cool as much air as a larger capacity 3 ton coil. Experts?
Yes it will. Typically a coil is sized a 1/2 ton larger than the a/c out side for efficiency, but a whole ton bigger should still work
Yes it will. Typically a coil is sized a 1/2 ton larger than the a/c out side for efficiency, but a whole ton bigger should still work
Installing a 3 1/2 ton condenser on a 3 tr evaporator will not function properly. There isn't enough evaporator coil surface area to absorb heat and vaporize refrigerant liquid for its return back to the condenser compressor. What can be done is a 3 ton condenser unit with a 3 1/2 evaporator coil.
That depends on 1) what indoor coil you have, 2) is the ductwork adequate to support 4 tons and 3) if the indoor coil and ductwork are suitable does the blower have the capacity to support 4 tons or 1600 cfm? If so it must be sped up.
yes, but you will overwork your compresser and you will have to change your txv
A 3 ton is one more than a 2 ton.
I have a 97 cavalier with a 95 engine and i had to replace the whole ignition module and the coil packs are 1/4 and 2/3 that's how they are numbered on the coil packs so 2 coil packs but make sure you know which one isn't firing to replace them and u will have to replace you spark plugs after that.
not very well. a 4 ton system needs about 1600 cfm to provide it's full capacity of cooling. a 3 ton furnace puts out about 1200 cfm. in addition, the evap coil typically attached to the furnace needs to match the tonnage of the outdoor unit. so, the evap coil must be 4 tons. If you currently have a 3 ton furnace and evap coil, the system will not work, and you will most likely ruin the compressor in the outdoor unit.
yes it can. you can you can only downsize a coil by .5 tons or up .the flowrator piston have to be be changed according the the condenser size don't ever try to go more than1/2 ton it would damage the system.
No, the air handler won't push enough air to keep the coil from freezing up.