Continue Learning about Engineering

How do you calculate 3 phase kWh from measuring the total phase current current?

In a balanced 3-phase system, if the three loads are star connected, the line current is equal to the load current. If the loads are delta connected, the line current is less than the load current by a factor of 1/sqrt(3).


How do you calculate 3 phase earth fault loop?

You can't have a three phase earth fault, you can have a phase to phase or a phase to earth fault. If you want the potential phase to earth fault current it will be your voltage times your impedance. If you want the phase to phase potential fault current then you should just double the above result.


Can a 3 phase commercial electric grill be used on single phase 120 with a converter?

Very unlikely. Its 3 phase for a reason, it needs a large voltage/current to power it, single phase won't provide that.


How three phase line current convert in single phase?

The current is the same in the three live wires. The voltage can be described as the line voltage (phase to neutral) or the phase voltage (phase to phase) which is larger by a factor of sqrt(3). So a line voltage of 230 v corresponds to a phase voltage of 400 v.


Why root 3 used in 3 phase system?

In a 3 phase, star connected system, the phase to phase voltage and phase to neutral voltage is calculated using root 3. That is, phase to phase voltage is root 3 times phase to neutral voltage. Also to calculate three phase power the voltage and current is multiplied by root 3 to obtain 3 phase power with unity power factor.AnswerIf you vectorially-add two quantities that are displaced from each other by 120 degrees, then the resulting quantity will be 1.732 (i.e. the square-root of 3) longer. Try it for yourself.So, for a wye (star) connected system, the phasor (vector) sum of two phase voltages will result in a line voltage that is 1.732 times larger than a phase voltage. For a balanced wye (star) connected load, the phasor sum of two phase voltages will result in a line current that is 1.732 larger than a phase current.

Related questions

What you basically want is will each phase take 26 Amps current for 15HP 3 phase 415VAC motor?

Yes. In a 3-phase motor, all 3 phases have the same current.


Why phase angle is zero when voltage and current are in phase?

1 & 3


How do you change the connection of single line to 3 phase line of DC motor?

There is no such thing as 3 phase to a DC motor. DC is direct current and is totally different from AC. 3 phase only exists in AC or Alternating Current


How do you calculate the total input current from a 3-phase power source when the current from each phase is known?

Add them upAnswerThere is no 'total' current in a three-phase system. The current flowing in each line (not 'phase') is considered separately. And you most definitely don't 'add them up'!


What is current in three phase and single phase?

All current is the passage of electric charges from one terminal to another through a conductor so there is no real difference in the type of current that flows in a 3 phase system compared to a single phase system.


How do you convert line current to phase current?

The current is the same in the three live wires. The voltage can be described as the line voltage (phase to neutral) or the phase voltage (phase to phase) which is larger by a factor of sqrt(3). So a line voltage of 230 v corresponds to a phase voltage of 400 v.


What is phase current?

A phase current is the current passing through a phase, whereas a line current is the current flowing through a line.


How do you calculate 3 phase kWh from measuring the total phase current current?

In a balanced 3-phase system, if the three loads are star connected, the line current is equal to the load current. If the loads are delta connected, the line current is less than the load current by a factor of 1/sqrt(3).


A delta connected 3 phase motor, shown above, draws a line current of 24 A from a 400 V supply, If fuse F3 blows, determine the current in each phase winding of the motor.IA = IC = IB=?

For proper working of any 3 phase induction motor it must be connected to a 3 phase alternating current (ac) power supply of rated voltage ...


When you have 56KVA available in 3 phase supply how much is your available current in 3 phase and how much in 1 phase?

In three phase: I = (three phase VA) / (sqrt(3) x (phase to phase voltage)) for single phase: I = (single phase VA) / ((phase to neutral voltage)) keep in mine three phase VA = 3 x (single phase VA), and phase to phase voltage = 1.732 x (phase to neutral voltage) Therefore the single phase and three phase currents are the same (ie, the three phase currents are the same in all three phases, or balanced). But don't get available current and available power confused (KVA is not the same as KW).


Why the 3 phase of high voltage conductor or cable transposed?

3 phase cable is transposed to minimize the effect of leakage/capacitance current.


How do you calculate 3 phase earth fault loop?

You can't have a three phase earth fault, you can have a phase to phase or a phase to earth fault. If you want the potential phase to earth fault current it will be your voltage times your impedance. If you want the phase to phase potential fault current then you should just double the above result.