answersLogoWhite

0

You may be able to turn up the blower speed but you will probably still not get the appropriate cfm. You may be able to swap out the blower but you may run into problems with fitting the new one in place or the proper sizing of the return and supply duct work.

User Avatar

Wiki User

15y ago

What else can I help you with?

Related Questions

Will a 4 ton condenser unit work with a 3 ton furnace?

not very well. a 4 ton system needs about 1600 cfm to provide it's full capacity of cooling. a 3 ton furnace puts out about 1200 cfm. in addition, the evap coil typically attached to the furnace needs to match the tonnage of the outdoor unit. so, the evap coil must be 4 tons. If you currently have a 3 ton furnace and evap coil, the system will not work, and you will most likely ruin the compressor in the outdoor unit.


Which item are part of the AC system?

The components of an air conditioning (AC) system typically include the compressor, evaporator coil, condenser coil, expansion valve, and refrigerant. The compressor circulates the refrigerant, the evaporator coil absorbs heat from the indoor air, and the condenser coil releases that heat outside. The expansion valve regulates the flow of refrigerant between the evaporator and condenser, ensuring efficient cooling. Together, these components work to maintain a comfortable indoor environment.


Will a 3ton coil work on a 3.5ton condenser?

It is not recommended to pair a 3-ton coil with a 3.5-ton condenser. Mismatched components can lead to decreased efficiency, poor performance, and potentially even damage to the system. It is best to use matching components for optimal operation.


88 Honda trx 350 has no spark coil is good what else could it be?

An 88 Honda trx 350 should have a set of points and a condenser under a side cover on the engine. If the points do not work properly of the condenser is bad then there will be no power going into the coil and there wont be a spark.


Can a 3 ton coil work with a 2 ton condenser?

Yes it will. Typically a coil is sized a 1/2 ton larger than the a/c out side for efficiency, but a whole ton bigger should still work


Can 3 ton a coil work with a 2 ton condenser?

Yes it will. Typically a coil is sized a 1/2 ton larger than the a/c out side for efficiency, but a whole ton bigger should still work


Do you have to have a 4 ton coil for a 4 ton ac unit?

The rating is technically a minimum. You could use a larger coil and have it work. But if its a Evaporator coil it will need to be matched on the far end with a similar or larger condenser coil. If the Condenser coil is larger it will probably just take a little more refrigerant.


What is the approximate cost of a furnace and ac for a 1000 sq ft house?

Cost may vary depends on the house size, accessibility, the amount of work involved in duct reworking, disconnecting/connecting gas electricity. Normally, it's better to replace AC/coil/Furnace all together, since a new furnace may not be compatible with old indoor blower /evaporator coil.


Can a 5 ton coil and furnace work with a 3 ton compresser?

No, it is not recommended to pair a 5 ton coil and furnace with a 3 ton compressor. The sizes need to be compatible for the system to operate efficiently and effectively. Mismatched components can lead to performance issues and potential damage to the system.


What size condenser do you need to match a 5ton 10 seer coil that is at least 9 years old?

A 5 ton 10 SEER condenser will do it, but you can no longer buy a 10 SEER condenser. Replacing the condenser and not matching it with the proper evaporator coil will nullify the SEER value stated on the new unit and your actual SEER and EER will be anyone`s guess so do not pay any attention to it. The coil is the least expensive component of the 3 and now would be the time to upgrade away from R 22 which is currently being phased out and will become very expensive in the near future. Something to consider if that 9 year old coil were to fail before the new condenser does or if you were to develop a troublesome leak. But if you are dead set against the coil replacement I suppose a 4.5 or 5 ton, depending on the climate where you live will work. Get the lowest SEER currently available (13) since it will mean nothing.


How much does a furnace cost for a 1800 square foot house?

Cost may vary depends on the house size, accessibility, the amount of work involved in duct reworking, disconnecting/connecting gas electricity. Normally, it's better to replace AC/coil/Furnace all together, since a new furnace may not be compatible with old indoor blower /evaporator coil. The real cost of installing a furnace vary lots of depending on the low end or high end product, accessories (media filter , humidifier) you like to have.


What are the key components of a heat pump condensing unit and how do they contribute to the overall efficiency of the system?

The key components of a heat pump condensing unit are the compressor, condenser coil, and fan. The compressor pressurizes the refrigerant, the condenser coil releases heat from the refrigerant, and the fan helps dissipate the heat. These components work together to efficiently transfer heat from inside to outside, making the system more energy-efficient.