Resistor or blower motor power module.
if it doesn't heat your heater core is most likely clogged and if it doesn't blow at all then the blower is messed up.
no it doesnt it has an auto shut down relay located under the hood. not a comon problem for them to go bad
Blown fuse, bad motor, bad blower motor switch, or a defective Blower Motor Resistor Pack.
if it doesnt work on 1 and 2 it could be a blower motor resistor but if it doesnt work at all check the fuses, relay and check voltage if it reads 12 v replace the motor
Could be your alternater.
Bad blower motor? Blown blower motor fuse? Bad fan switch? Bad blower resistor pack?
I had the same problem on my 95 LHS. Turned out to be the fuse connector had gotten so hot it melted the plastic of the fuse box surrounding it! I bent the fuse blades a bit and reinserted it. It worked for a while. I had a shop cut the wires to the fuse box and install an in-line fuse holder for the 25-amp fuse. No problems at all with it now. Hope this helps!
check the blower motor resistor located on fire wall behind washer fluid tank
Yes, pollution is a problem in Germany. Areas with high levels of air pollution have been identified, particularly in cities and near industrial sites. The government has implemented measures to address this issue, including promoting green technologies and reducing emissions from vehicles.
I think you have problem with the blower resistor. Please follow the procedure to check. * remove the connector to the blower motor. * use voltmeter to check the voltage. * connect one probe to the ground and the other probe to the 3.0R/w of the motor supply. * turn on the the blower motor with dial, you should read supply voltage, 12Vdc. * if you have positive voltage at the 3.0R/w then you should check the blower resistor and blower switch. blower switch supplies battery negative to the blower motor through the blower resistor. if you need further help please just let me know.
A Ryobi leaf blower will fail to start if the spark plug is fouled or it has run out of fuel. Using the incorrectly mixed fuel will also prevent it from starting.
the blower resistor is bypassed on high. a direct path to ground. if high is the only operational speed the resistor is bad.