A single speed permanent split capacitor AC induction motor has two separate pairs of series wound stator windings arranged at right angles to each other around the central rotor. The main run winding is connected directly to the AC power source while the secondary start winding is connected to the same source with a capacitor in series with it. The capacitor causes an electrical phase shift to the power in the start winding relative to the run winding, to produce a rotating magnetic field around the rotor which can start it turning. Since the capacitor remains in the circuit while the motor is running it's called a permanent split capacitor design.
A start capacitor is wired in series with the motor's start winding via a centrifugal start switch. The switch disconnects the capacitor and start winding once the motor has reached a pre-determined minimum speed. The motor then continues to run on its main field winding. A different design uses a "start-and-run" capacitor which remains in circuit whilst the motor is running.
Most ceiling fans use a type of motor known as a "permanent split capacitor motor". These motors have two coils, a "start" and a "run" winding. A capacitor is connected in series with the start winding to insert a phase shift, but once the motor is up to speed it becomes an auxiliary winding. In order to reverse the motor, the capacitor is applied to the "run" winding which then becomes the "start" winding. In some cases the windings may have taps to provide different speeds, in others the value of the start/run capacitor is lowered to provide lower speeds. Yet other designs will have additional capacitors wired in series with the motor as a whole to regulate speeds.
No, they are two different concepts. The start capacitor is used in conjuction with a starting winding on a single-phase induction motor to produce a small component of rotating field inside the motor. This ensures it rotates the desired way. The run capacitor is used to correct the power-factor of the motor, which reduces the current drawn from the supply for the same amount of power.
The main parts are the stator and the rotor.After that depends on the type of single phase motor. This includes capacitors (start and/or run),centrifugal switch (stationary and rotary) Also there are usually two windings,a start and a run winding. In its most basic form the start and run winding are connected together at one end of the windings (common) the other end of the run winding connected via a centrifugal switch and/or run capacitor to the other end of the start winding. Power is supplies to the run winding terminals. The start capacitor is fitted in series with the centrifugal switch, allowing it to be disconnected once rotation speed is reached.
A capacitor start motor is a split phase motor that uses a capacitor in series with the start winding to cause a greater phase shift, resulting in greater starting torque. It uses a centrifugal switch to switch out the start winding and capacitor once the motor is up to speed. I assume this switch is what you're referring to as a "relay".
In the case of a capacitor-start/run single-phase induction motor, the main field is provided by the main (running) winding, and the capacitive branch is the auxiliary winding. In the case of a capacitor-start motor, the main winding is the running winding and the auxiliary winding is the starting winding.
The run winding of a single phase capacitor start motor has a lower resistance than the start winding.
This is for a single voltage motor. If you consider the forward rotation as counter clockwise (CCW) when looking at the motor from the end opposite the drive end, then the connections will be, L1 - terminals 1 and 8, L2 - terminals 4 and 5. To reverse the rotation (CW), then the connections will be, L1 - terminals 1 and 5, L2 - 4 and 8.
The start winding needs a capacitor in series with it in order to produce a phase shifted magnetic field that will develop the torque necessary to bring the rotor up to operating speed. Once operating speed it obtained, a centrifugal switch opens and disconnects the start winding - the rotor's inertia can then keep it going as needed.
A split-phase motor uses a centrifugal switch to energize and de-energize the start winding. The switch is connected in series with the start winding circuit and is typically set to open when the motor reaches about 75-80% of its operating speed, disconnecting the start winding from the power supply.
I think the resistance value of starting winding is less than the running winding of the single phase motor