Use a Mega Ohm meter, alaso known as a "Megger". Depending on the type of insulation you need to figure out what voltage to use. The test voltage can range from 500V to 5KV and you have to be sure you know what you are doing and use the right one....
<><><>
As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.
Before you do any work yourself,
on electrical circuits, equipment or appliances,
always use a test meter to ensure the circuit is, in fact, de-energized.
IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOB
SAFELY AND COMPETENTLY
REFER THIS WORK TO QUALIFIED PROFESSIONALS.
An ohm meter measures resistance in a circuit, not leakage in wire insulation. To measure insulation resistance or leakage in wire insulation, you would typically use a megohmmeter or insulation resistance tester, which applies a higher voltage than an ohm meter to test the integrity of the insulation.
Because ordinary ohmmeters are calibrated to measure a range of resistance values that are significantly lower than the resistance of insulation. It should also be realised that we usually test insulation resistance while subjecting the insulation to a high electric field, which a normal ohmmeter is incapable of producing.
Insulation resistance test: This test is used to find the insulation resistance of motor for 1 min or 10 min through high voltage insulation tester. By this we can find the insulation level. Polarization index: This is the ratio between insulation resistance for 10 min to insulation resistance for 1 min.
I think you mean, 'insulation' resistance! It's the resistance of insulation, normally expressed in megohms.
The best insulation for a basement is typically rigid foam insulation, as it provides good thermal resistance and moisture resistance.
The insulation resister tester was invented by Ohm and was instantly the industry standard when dealing with testing the safety and effeciency of electrical products according to the Electrical Construction & Maintenance web site ecmweb.
High resistance means insulation
The insulation resistance remains the same throughout the entire length of the conductor.
One common method to test the solid layer on an insulator is the Megger test, where a high voltage is applied across the insulation to measure its resistance. Another method is the insulation resistance test, which measures the resistance of the insulation to detect any defects. Additionally, visual inspection can also be used to check for any visible damage or contamination on the insulator's surface layer.
The polarization index (PI) of a motor is measured by applying a DC voltage to the motor's winding and observing the insulation resistance over time. Typically, the insulation resistance is measured at intervals of 1 minute and 10 minutes using a megohmmeter. The PI is calculated by dividing the resistance at the 10-minute mark by the resistance at the 1-minute mark. A higher PI indicates better insulation quality and lower moisture or contamination levels.
Meggar is a hand driven tool for measuring insulation resistance and earth resistance.
A megger is an electrical instrument that is used to measure the resistance of insulation by applying a DC voltage to the conductor. One lead is connected to the conductor and the other lead is connected to ground. Safe insulation reading to ground should be above 2,000,000 ohms or 2 megs.