18-20psig suction
250-270 psig discharge
In freezers pressures are ok .I got it ,but the mention pressure of suction 18-20
discharge 250-270 at what temprature in centegrade it should be.
42
Mixing 404A refrigerant with R12 is not recommended, as they are incompatible and can lead to system damage, decreased efficiency, and safety hazards. R12 is a CFC refrigerant, while 404A is a blend of HFCs that operates at different pressures and thermodynamic properties. Additionally, mixing refrigerants can complicate recovery and recycling processes, making it difficult to maintain compliance with environmental regulations. It's best to use the specified refrigerant for your system.
The recommended high pressure for 404A refrigerant in a walk-in cooler is around 250-300 psi, while the low pressure should be around 50-65 psi. These values may vary depending on factors such as the ambient temperature and the specific system design. It's important to consult the equipment manufacturer's guidelines for precise pressure recommendations.
In a 404A refrigerant bench cooler, the typical operating pressures can vary based on the specific system design and operating conditions. However, the suction pressure usually ranges from about 10 to 30 psi, while the discharge pressure typically falls between 200 to 250 psi. It's essential to consult the manufacturer's specifications for the exact pressures optimal for the particular unit in use. Regular monitoring ensures efficient operation and helps prevent system damage.
what is suction pressure of r407a
18-20psig suction 250-270 psig discharge In freezers pressures are ok .I got it ,but the mention pressure of suction 18-20 discharge 250-270 at what temprature in centegrade it should be.
No, refrigerants cannot be blended.
R-404A is not compatible with R-12 systems due to differences in chemical composition and operating pressures. While R-404A is a hydrofluorocarbon (HFC) refrigerant, R-12 is a chlorofluorocarbon (CFC), and their properties require distinct system components. Converting an R-12 system to use R-404A typically involves replacing the compressor, expansion valve, and other components to ensure proper functionality and efficiency. Always consult a qualified technician for refrigerant conversions.
if room tem is 70f 15psi
if room tem is 70f 15psi
Mixing refrigerants 404A and 410A is not recommended. Each refrigerant has a different composition and pressure characteristics, which can lead to system inefficiencies, potential damage, and safety hazards. Additionally, mixing refrigerants can violate environmental regulations and void equipment warranties. It's best to use the specified refrigerant for your system to ensure optimal performance and compliance.
For a R-404A ice maker, the low side pressure typically ranges between 20 to 30 psi, while the high side pressure should be around 200 to 250 psi. These pressures can vary slightly based on the specific ice maker model and ambient conditions. Always check the manufacturer's specifications for the most accurate pressure readings. Proper monitoring is essential to ensure efficient operation and prevent potential issues.