answersLogoWhite

0

The system is going out on either high limit or thermal cut off. 107 is a very high ambient temperature. Therefore your head pressure is through the roof. The condensing section of an A/C unit removes the heat from the refrigerant. You are trying to remove heat with 107 degree air, not going to work too well. What you are doing with the hose is cooling it down with the water, bringing the head pressure back down, the system will start again until it overheats. You should consider either a ground source heat pump or an addtional system for the household. Ground source heat pump uses water from the ground as the condensing section. No 107 degree air across a coil, but say 70 degree water. If that is not possible an additional system would help as it would bring the heat load in the house down, bringing down your pressures. There is nothing wrong with the equipment, it is just doing what it is supposed under such extreme conditions

User Avatar

Wiki User

16y ago

What else can I help you with?

Related Questions

What happens to the compressor superheat when the outdoor ambient temperature increases?

When the outdoor ambient temperature increases, the compressor superheat tends to decrease. This is because higher ambient temperatures cause the refrigerant to evaporate at a lower temperature, leading to lower superheat levels. This could potentially lead to overloading the compressor. Regular maintenance and adjustments may be needed to ensure optimal system performance.


When using the charging chart in fig 10.17 what happens to the compressor superheat when the out door ambient temperature increases?

As the outdoor ambient temperature increases, the compressor superheat will decrease. This is because the increased heat load on the system causes the refrigerant to evaporate faster, resulting in lower superheat levels. It is important to monitor and adjust the system to maintain optimal superheat levels for efficient operation.


Does the outdoor compressor run if you have an electric heat strip in your indoor unit?

Yes a compressor will run the entire heating and cooling cycle, unless its in emergency heat in which case you will not have compressor operation. Defrost cycle is the AC mode except the outdoor fan is de energized to assist in the defrosting of the outdoor coil.


Does the outside compressor of an ac need to lay flat?

Yes, the outdoor compressor unit of an air conditioning system should be installed on a flat, level surface. This ensures proper drainage of condensate and optimal airflow, which is essential for efficient operation. An uneven installation can lead to mechanical issues and reduced performance over time. Always follow the manufacturer's installation guidelines for best results.


3 year old central air unit will not run only inside blower fan goes on Circuit breaker is ok outdoor switch is on thermostat to cool and lowered indoor tempPossible causes?

Just to confirm: with central air conditioning, there are typically 2 circuit breakers: one for the inside blower unit (which is obviously working), and one breaker set for the outdoor unit. It's this second "double breaker" I'd look at first. Often, breakers trip and don't look like they're tripped. The only way to check for sure is to switch the breaker off, looking for a solid "click," and then turning it back on again. If nothing still runs outside, the possible culprits are as follows:1. If the "condensate" -- the moisture removed at the indoor evaporator coil -- is routed to a "condensate pump," it may be that that pump's sump is full. Is the condensate pump energized? Does it have a "safety switch" that shuts off the air conditioner if the sump fills up? If the pump's sump is full, and there's power to the pump, then the condensate pump may need to be replaced.2. Burnt/broken power or control wiring to the outdoor unit.3. Burnt/broken contactor in the outdoor unit.4. Deluxe outdoor unit senses a loss of refrigerant and shuts itself off (via the "low pressure safety" control).5. Failed outdoor fan motor has overheated the compressor, so neither runs.6. Failed compressor (due to internal failure or problems in the start components or burnt/broken wiring at the compressor terminals) keeping the compressor off. The condenser fan motor is kept off by a "condenser fan cycling control" which normally starts it after the compressor has built up refrigerant pressure.


What are the best patio lights to create a cozy and inviting outdoor atmosphere?

String lights are often considered the best patio lights for creating a cozy and inviting outdoor atmosphere. They provide a warm and ambient glow that can enhance the overall ambiance of your outdoor space.


How does the outdoor ambient temperature affect the head pressure?

The outdoor ambient temperature significantly influences head pressure in refrigeration and air conditioning systems. As the temperature increases, the heat absorbed by the refrigerant rises, leading to higher head pressure due to increased vapor pressure in the condenser. Conversely, lower ambient temperatures can reduce head pressure as the refrigerant condenses more efficiently. Maintaining optimal head pressure is crucial for system efficiency and performance.


Where is the ambient temp sensor located in 94 Labaron Landau?

The ambient temp sensor on a 94 Labaron Landau is located under the hood, near the front of the compartment. It detects the outdoor temperature and allows the vehicle to make adjustments accordingly.


Why does Ac trip breaker when on heat it doesn't?

That tells me the problem is with the outdoor unit. Most likely a dead compressor or fan motor. Additionally, your indoor and outdoor units are not on the same breaker.


What is a contactor for a Central Air Unit?

The relay actuated by the thermostat which starts and stops the compressor and condenser fan in the outdoor unit.


Constantly running air compressor for a Ruud electric heat pump What does this mean?

If the outdoor temp is around 35*or lower, it probably means nothing other than you are near the balance point when the unit should switch to auxiliary (electric) heat. At 35* or so & lower the heat pump alone can no longer extract heat from the ambient air effectively and you may also develop ice over problems on the outdoor unit. If these are not the temps you are experiencing when this occurs you should have it looked at.


What are some design ideas for outdoor patios with fire pits?

Some design ideas for outdoor patios with fire pits include incorporating comfortable seating, adding ambient lighting, using natural materials like stone or brick for the fire pit, and creating a cozy atmosphere with plants and outdoor rugs.