When it comes to HVAC systems, purging the line to the refrigerant cylinder is an important step in the refrigeration process. This is done after evacuation, and before charging, to ensure that the system is properly charged and functioning correctly.
The purpose of purging is to remove any non-condensable gases that are present in the system. Non-condensable gases can be any gas that is not part of the refrigerant and can cause many problems in the system. These gases can cause the system to be inefficient, as they can reduce the overall efficiency and cause the system to be less effective. Non-condensable gases can also cause the system to operate at higher pressures, and this can lead to damage to the system.
By purging the line to the refrigerant cylinder, any non-condensable gases are removed from the system. This allows for the system to be charged with the correct amount of refrigerant and operate at the proper pressures. Without the non-condensable gases, the system will be able to operate more efficiently and effectively.
Another important reason to purge the line to the refrigerant cylinder is to ensure that the system is not overcharged. If the system is overcharged, it can cause a variety of problems. Overcharging can cause the system to become overly pressurized, and this can lead to component failure. It can also cause the system to be inefficient, as the system will be unable to cool properly. By purging any excess refrigerant prior to charging, it ensures that the system is not overcharged and will operate at the proper pressures.
Overall, purging the line to the refrigerant cylinder is an important step in the refrigeration process. It ensures that the system is properly charged and functioning correctly, and it also helps to prevent overcharging and component failure.
The line to the refrigerant cylinder is purged after evacuation and before charging to remove any air, moisture, or contaminants that may have entered the line during the evacuation process. This step ensures that only clean refrigerant enters the system, preventing potential damage and inefficiency. Purging also helps maintain the integrity of the refrigerant charge and ensures optimal system performance.
The cylinder should be evacuated
Freon weight in HVAC systems is typically measured using a refrigerant scale. The scale is placed under the refrigerant cylinder, and the system is charged until the desired weight of refrigerant is reached. The weight of the refrigerant can then be monitored on the scale to ensure proper charging.
When charging refrigerant as vapor, the refrigerant is added to the system in its gaseous form. As the vapor enters the system, it needs to condense into a liquid in order to increase the pressure. This condensation process causes the pressure to decrease initially before the pressure starts to rise as more vapor enters and condenses into liquid form.
Probably not, how long did it run before the mix up was discovered? All of the refrigerant has to come out and be properly disposed of, then a good evacuation and recharge. You did not say which refrigerant was the correct one for the machine, but either way it all has to go.
The vapor pressure in the system's shells should be equal to the saturation pressure of the refrigerant at the temperature at which the system is being charged. This ensures that the refrigerant enters the system in a liquid state to prevent damage from excessive liquid refrigerant entering the compressor. It is important to follow the manufacturer's recommendations for proper charging procedures when working with refrigerants like R-11.
To endure that the ONLY gas in the system is refrigerant.
Refrigerant System ChargeWARNING: REFER TO THE APPLICABLE WARNINGS AND CAUTIONS FOR THIS SYSTEM BEFORE PERFORMING THE FOLLOWING OPERATION.After all refrigerant system leaks have been repaired and the refrigerant system has been evacuated, a refrigerant charge can be injected into the system. For the proper amount of the refrigerant charge, refer to the Underhood HVAC Specification Tag. An R-134a refrigerant recovery/recycling/charging station that meets SAE Standard J2210 must be used to charge the refrigerant system with R-134a refrigerant. See the operating instructions supplied by the equipment manufacturer for proper care and use of this equipment.REFRIGERANT CHARGE CAPACITYNOTE: Always refer to the underhood HVAC Specification Tag for the latest fill specification for the vehicle being serviced.CHARGING PROCEDUREEvacuate the refrigerant system .A manifold gauge set and a R-134a refrigerant recovery/recycling/charging station that meets SAE Standard J2210 should still be connected to the refrigerant system.Measure the proper amount of refrigerant (1.88 lb) and heat it to 52°C (125°F) with the charging station. See the operating instructions supplied by the equipment manufacturer for proper use of this equipment.Open both the suction and discharge valves, then open the charge valve to allow the heated refrigerant to flow into the system.When the transfer of refrigerant has stopped, close both the suction and discharge valves.If all of the refrigerant charge did not transfer from the dispensing device, open all of the windows in the vehicle and set the heater-air conditioner controls so that the compressor is engaged and the blower motor is operating at its lowest speed setting. Run the engine at a steady high idle (about 1400 rpm ). If the compressor will not engage, test the compressor clutch control circuit and repair as required.Open the suction valve to allow the remaining refrigerant to transfer to the refrigerant system.WARNING: TAKE CARE NOT TO OPEN THE DISCHARGE (HIGH PRESSURE) VALVE AT THIS TIME.Close the suction valve and test the system performance.Disconnect the charging station and manifold gauge set from the refrigerant system service ports.Reinstall the caps onto the refrigerant system service ports.Run the HVAC Control Cooldown test to verify proper operation.
As a precaution.
No.
why applay refrigerant oil to the flare cone before making a flare