Cfbc stands for circulating fludised bed combustion where as afbc is for atmospheric fluidise bed combustion afbc bed fluidising velocity is approx 4 m/s and in cfbc boiler fluidising velocity is 9-10 m/s. cfbc having low SOx & NOx comparative with afbc cfbc having higher efficiency up to 98.5 % then afbc boiler,cfbc boiler power consumption is more comparative to afbc.
The wall seal blower in a Circulating Fluidized Bed Combustion (CFBC) boiler serves to maintain a proper seal between the combustion chamber and the external environment. By creating a slight negative pressure, it prevents the escape of flue gases and ensures efficient combustion by maintaining the required airflow. Additionally, it helps to enhance the overall efficiency of the boiler by optimizing the circulation of the bed material and improving the combustion process.
the pressure of the root blower is higher then the wind box pressure, because what ever the unburnt particle come from cyclone separator is collect in return leg this unburnt particle return back into combustion chamber so the function of root blower is to continuous circulation.
For getting better efficiency from boiler, coal is pulverized in mills (powder form) before entering into boiler along with hot air. This is done in order to control damage to boiler tubes and plates due to high (but cheap) sulphur content in coal. These types of boiler are usually called super critical boiler and works on high pressure (3600psi) and temperature (610 degree C) unlike sub critical boilers. alok bh.
All boilers are made to a pressure specification and in most countries any pressure vessel over a certain size is required to be periodically inspected and pressure tested to ensure it is fit for purpose. In addition to being in sound condition, the boiler is also expected to have some form of pressure relief valve. This is of sufficient size to vent off excess pressure before it gets to an explosive situation. It is obviously important that the pressure of this device is set to a lower level than the ultimate pressure specification of the boiler. Even quite small boilers, like those in coffee makers need to be inspected. Some boilers are 'gas fired' such as home heating boilers. These have a device called a thermocouple that detects the flame and is linked to the gas valve. If the flame goes out, or the burner does not ignite when gas is released in the boiler, it will shut the gas off. Typically gas fired boilers have a number of devices that will shut off the gas in the event that something doesn't work. This means that if the gas supply pipe is in sound condition, the boiler itself cannot leak gas and cause an explosion.
1300 mmWc @ full load
Cfbc stands for circulating fludised bed combustion where as afbc is for atmospheric fluidise bed combustion afbc bed fluidising velocity is approx 4 m/s and in cfbc boiler fluidising velocity is 9-10 m/s. cfbc having low SOx & NOx comparative with afbc cfbc having higher efficiency up to 98.5 % then afbc boiler,cfbc boiler power consumption is more comparative to afbc.
Circulating fluidised bed combustion
The wall seal blower in a Circulating Fluidized Bed Combustion (CFBC) boiler serves to maintain a proper seal between the combustion chamber and the external environment. By creating a slight negative pressure, it prevents the escape of flue gases and ensures efficient combustion by maintaining the required airflow. Additionally, it helps to enhance the overall efficiency of the boiler by optimizing the circulation of the bed material and improving the combustion process.
cyclone is used for to recycle the unburnt and heavy particles into com-buster
how we calculate the coal consumed to generate xxx MW say 12 hrs or 24 hrs in CFBC boiler please help
drum level maintain at48to52% O2 4% id draft _2to+2
loop seal is provided to stop the material from furnace to return leg back.It works with the help of diffrential pressure.There is the difference in the pressure of air beteen furnace and return leg.
The boiler in which fluidisation and combustion is done in the bed with the help of (pa,sa&ta)air and ash(un burnt particle) is re-used through cyclone and siphone to the bed is called cfbc boiler.
the pressure of the root blower is higher then the wind box pressure, because what ever the unburnt particle come from cyclone separator is collect in return leg this unburnt particle return back into combustion chamber so the function of root blower is to continuous circulation.
CFBC was created on 1946-11-21.
500 MW Boiler is sub-critical Boiler which generates steam at pressure lower than the critical pressure ie below 221.2 kg/sqcm. where as the 660 MW boiler is super critical boiler which operates steam pressure above critical pressure.