answersLogoWhite

0

No, they are not the same, but 1 is part of 2.

Iodometric titration is just one of the (larger) group (or class) of oxidimetric titrations, which in turn is part of the much (larger) group (or class) of volumetric analysis method.

User Avatar

Wiki User

14y ago

What else can I help you with?

Continue Learning about Chemistry

What are iodometric and iodometric titration?

Iodometric titration involves determining the concentration of a substance by measuring the amount of iodine generated in a reaction. Iodometric titration, on the other hand, refers to a type of redox titration that uses iodine as the titrant to determine the amount of a substance, typically an oxidizing agent, present in a sample.


Why analysis of Cu from brass solution is considered as an iodometric titration?

Copper in brass can be oxidized to Cu2+ by iodine in a redox reaction. The iodine acts as the titrant in the reaction and the copper is being titrated. It is considered an iodometric titration due to the involvement of iodine in the titration process.


Why thiosulphate titration is called as redox titration?

A thiosulfate titration is mostly carried out to determine the amount of iodine present in the solution. In these reactions, thiosulfate ion acts as the reducing agent. This types titrations are often called as 'iodometric titrations'.


Why you do not use H2SO4 in iodometric titration?

Using H2SO4 in iodometric titration can lead to the formation of H2O2, which interferes with the reaction. It can also oxidize iodide ions prematurely, affecting the accuracy of the titration. Therefore, a different acid like HCl is typically used in iodometric titration.


What is the difference between iodometric titration and iodimetric titration?

Iodometric titration involves the titration of iodine with a reducing agent, while iodimetric titration involves the titration of iodide with an oxidizing agent. In iodometric titration, iodine is detected by a starch indicator to determine the end point, while in iodimetric titration, iodide ion concentration is determined by titration with a standard solution of an oxidizing agent.

Related Questions

What are iodometric and iodometric titration?

Iodometric titration involves determining the concentration of a substance by measuring the amount of iodine generated in a reaction. Iodometric titration, on the other hand, refers to a type of redox titration that uses iodine as the titrant to determine the amount of a substance, typically an oxidizing agent, present in a sample.


Why analysis of Cu from brass solution is considered as an iodometric titration?

Copper in brass can be oxidized to Cu2+ by iodine in a redox reaction. The iodine acts as the titrant in the reaction and the copper is being titrated. It is considered an iodometric titration due to the involvement of iodine in the titration process.


Why thiosulphate titration is called as redox titration?

A thiosulfate titration is mostly carried out to determine the amount of iodine present in the solution. In these reactions, thiosulfate ion acts as the reducing agent. This types titrations are often called as 'iodometric titrations'.


Why you do not use H2SO4 in iodometric titration?

Using H2SO4 in iodometric titration can lead to the formation of H2O2, which interferes with the reaction. It can also oxidize iodide ions prematurely, affecting the accuracy of the titration. Therefore, a different acid like HCl is typically used in iodometric titration.


What is the difference between iodometric titration and iodimetric titration?

Iodometric titration involves the titration of iodine with a reducing agent, while iodimetric titration involves the titration of iodide with an oxidizing agent. In iodometric titration, iodine is detected by a starch indicator to determine the end point, while in iodimetric titration, iodide ion concentration is determined by titration with a standard solution of an oxidizing agent.


What is the function of starch solution in the redox titration?

Starch solution is used as an indicator in redox titrations to detect the endpoint of the titration. It forms a complex with triiodide ions to produce a blue-black color when excess iodine is present, indicating that the reaction has reached completion. This helps in determining the equivalence point of the titration.


Why use NaHCO3 for iodometric titration?

Sodium bicarbonate (NaHCO3) is used in iodometric titration as a reaction enhancer to neutralize excess acids that may interfere with the redox reaction between iodine and the analyte being titrated. By maintaining a slightly basic pH, NaHCO3 helps stabilize the iodine solution, ensuring more accurate and reliable results.


Can we carry out an iodometric titration using a potentiometer?

No, iodometric titration is typically done using a standard titration setup with a burette and indicator to detect the endpoint. A potentiometer measures the voltage produced in a system, making it unsuitable for this type of titration.


What is iodometric titration?

In this titration iodine is liberated ....Added:... from (excess of) iodide by an oxidant. The Iodine is then titrated with thio (di-sodium thio-sulfate) and starch as indicator added just before the expected equivalence point.


What is redox titration?

Redox titration is a type of titration that involves a redox reaction between the analyte and titrant. In this titration, the endpoint is determined by monitoring the change in oxidation state of the analyte. It is commonly used to determine the concentration of oxidizing or reducing agents in a sample.


What is iodometry and iodimetry titration?

Iodometric titration is synonymous with redox titration method. Iodine is a universal laboratory reagent because it reacts directly with an array of organic and inorganic substances. Since iodometric titration is a form of redox or oxidation-reduction reaction, it can accurately measure the amount of oxidizing or reducing agents in a chemical reaction. Also, it can be reversed to either direction in an iodine/iodide reaction.


What is the theory of the redox titration?

Redox titration is a type of titration based on a redox reaction between the analyte and titrant. The theory behind redox titration is that the number of electrons transferred in the reaction is used to determine the amount of substance being analyzed. This is typically done by monitoring the change in concentration of a redox indicator or analyzing the endpoint using a potentiometric method.