Titration with strong base requires eg. methyl red, changing to yellow at 6.2, but it endpoint may come too early when the sulfonic acid is weaker than acetic acid: OK if pKa < 4.5 .
So it's safer to use phenolphaleine (purple at pH=8.5) for acids with pKa < 8
Phenolphthalein is commonly used as the indicator for the titration of a weak acid and a strong base. It changes color from colorless to pink at the equivalence point of the titration when the weak acid is completely neutralized by the strong base.
Phenolphthalein is used as an indicator during the titration of tartaric acid because the pH at which phenolphthalein changes color (around pH 8.2-10) is close to the equivalence point of the titration of tartaric acid with a strong base like NaOH. This makes it a suitable indicator for detecting the endpoint of the titration when the acid has been completely neutralized by the base.
For the titration of a strong acid, the indicator typically used is phenolphthalein. Phenolphthalein changes color in the pH range of 8.2 to 10, which is suitable for titrating a strong acid with a strong base to determine the equivalence point.
The blank titration is used to determine the exact amount of acid needed to neutralize any impurities in the titration setup, such as the indicator and solvent. This additional volume of acid is accounted for in the blank titration and is subtracted from the volume of acid used in the titration with the oil sample.
Phenolphtalein is an indicator used to find the endpoint of a reaction (specifically an acid-base reaction). It has a pH range of 8.3 to 10.0 which means it can be used for a strong acid to strong base titration or a weak base to strong acid titration. Phenolphthalein is clear when it is in the presence of acid and pink when it is in the presence of a base.
Phenolphthalein is commonly used as the indicator for the titration of a weak acid and a strong base. It changes color from colorless to pink at the equivalence point of the titration when the weak acid is completely neutralized by the strong base.
Yes - it's used in acid-base titration.
Phenolphthalein is used as an indicator during the titration of tartaric acid because the pH at which phenolphthalein changes color (around pH 8.2-10) is close to the equivalence point of the titration of tartaric acid with a strong base like NaOH. This makes it a suitable indicator for detecting the endpoint of the titration when the acid has been completely neutralized by the base.
For the titration of a strong acid, the indicator typically used is phenolphthalein. Phenolphthalein changes color in the pH range of 8.2 to 10, which is suitable for titrating a strong acid with a strong base to determine the equivalence point.
The blank titration is used to determine the exact amount of acid needed to neutralize any impurities in the titration setup, such as the indicator and solvent. This additional volume of acid is accounted for in the blank titration and is subtracted from the volume of acid used in the titration with the oil sample.
pH range of indicator should be in the rapid pH gradient.
Phenolphtalein is an indicator used to find the endpoint of a reaction (specifically an acid-base reaction). It has a pH range of 8.3 to 10.0 which means it can be used for a strong acid to strong base titration or a weak base to strong acid titration. Phenolphthalein is clear when it is in the presence of acid and pink when it is in the presence of a base.
Phenolphtalein is used as indicator for titration in chemistry. Also as a pH indicator: pink in basic solutions and colorless in acidic solutions. Phenolphatelein can be used to check blood in forensic problems or as a component of some inks.
it is used as an acid-base indicator
This titration is based on the neutralization reaction between oxalic acid and sulfuric acid; a pH indicator is used.
Both HCl and oxalic acid are acids. Therefore, since there is no alkali present, these compounds do not undergo neutralization. So there is no suitable indicators for the addition of these two reagents.
Potassium permanganate is used as a self-indicator in the titration of oxalic acid because the initial pink color of potassium permanganate is decolorized in the presence of oxalic acid due to its reducing properties. The endpoint of the titration is reached when all the oxalic acid has reacted with the potassium permanganate, causing the pink color to persist. This change in color helps in determining the equivalence point of the titration.