Adding an indicator in the middle of a titration of residual chlorine helps to visually identify the endpoint of the reaction. The indicator changes color at the equivalence point, indicating that all the chlorine has reacted. This helps to determine the amount of titrant required, making the titration more accurate and precise.

User Avatar

AnswerBot

1y ago

What else can I help you with?

Continue Learning about Chemistry

Why in titration of kmno4 no indicator is used?

In the titration of KMnO4, no indicator is used because KMnO4 is a self-indicating titrant. It undergoes a color change from purple to colorless (or brown) at the endpoint of the titration, which makes it unnecessary to add an external indicator. The precise endpoint can be easily detected visually, making the use of an indicator redundant.


Why you add starch at the end of titration?

Starch is added at the end of titration as an indicator to signal the endpoint of the reaction. It forms a complex with the iodine produced during the titration, resulting in a color change from clear to blue-black, indicating that the titration is complete.


Why is indicator added to a pipette solution before titration?

I'm not sure what you really mean. There wouldn't be any point adding it afterwards! It's there to reveal the end point of your titration. You could add it when you thought you were near the end point, but it's easier to put it in before you start.


What is the titration flask?

A titration flask is a glass vessel with a narrow neck and a flat bottom used in titration experiments. It typically has volume markings for precise measurement of liquids added or titrated during the experiment.


Why starch indicator is not added right from the beginning of titration in iodometry?

Starch indicator should not be added at the beginning of an iodometry titration because iodine can form a complex with the starch, resulting in a blue-black color that can obscure the endpoint. It is best to add the starch indicator near the endpoint, when the iodine is almost completely reacted, to help visualize the color change.

Related Questions

Why in titration of kmno4 no indicator is used?

In the titration of KMnO4, no indicator is used because KMnO4 is a self-indicating titrant. It undergoes a color change from purple to colorless (or brown) at the endpoint of the titration, which makes it unnecessary to add an external indicator. The precise endpoint can be easily detected visually, making the use of an indicator redundant.


Why you add starch at the end of titration?

Starch is added at the end of titration as an indicator to signal the endpoint of the reaction. It forms a complex with the iodine produced during the titration, resulting in a color change from clear to blue-black, indicating that the titration is complete.


Can you add a salt water system to an already chlorinated pool?

Yes, just install the chlorine generator and add the salt. Your new system will replace the need for residual chlorine.


How can i determine the available chlorine in Sodium hypochlorite (Bleach) by titration with Sodium Thiosulfate?

To determine the available chlorine in sodium hypochlorite (bleach) using titration with sodium thiosulfate, first, dilute the bleach sample and then add an excess of potassium iodide, which reacts with the chlorine to form iodine. Next, titrate the liberated iodine with a sodium thiosulfate solution until a faint yellow color disappears, indicating that all iodine has reacted. The endpoint can be further refined with starch indicator, which changes color when iodine is fully reduced. Finally, calculate the available chlorine concentration based on the volume of sodium thiosulfate used in the titration.


Why is indicator added to a pipette solution before titration?

I'm not sure what you really mean. There wouldn't be any point adding it afterwards! It's there to reveal the end point of your titration. You could add it when you thought you were near the end point, but it's easier to put it in before you start.


What is the titration flask?

A titration flask is a glass vessel with a narrow neck and a flat bottom used in titration experiments. It typically has volume markings for precise measurement of liquids added or titrated during the experiment.


Why starch indicator is not added right from the beginning of titration in iodometry?

Starch indicator should not be added at the beginning of an iodometry titration because iodine can form a complex with the starch, resulting in a blue-black color that can obscure the endpoint. It is best to add the starch indicator near the endpoint, when the iodine is almost completely reacted, to help visualize the color change.


Describe a method to visually detect the end point of a titration without the use of instruments?

The method used most often in chemistry labs is by use of a pH indicator in the sample being titrated. When you reach the titration point, the indicator will change colors, demonstrating the end point of the titration.


Why is a small amount of indicator added during titration?

An indicator shows when we have added just enough of the second reagent to react with the first. If you mean why do we add only a small amount of indicator, it is to keep the answer accurate. Some of the reagent is used changing the indicator so the answer is always slightly bigger than perfection, and the more indicator you add, the larger the error.


How do you determine the end point from titration in acid base titration process?

it depends on the indicator used, i.e. phenolphthalein is the most popular. this is colourless in acid, purple in base, very identifiable. Keep actively swirling and when it is expected to turn (figured from a rough titration beforehand) add very slowly dropwise untill the colour turns.


Can you provide me with the proper procedure for conducting a titration, as outlined in the lab manual?

To conduct a titration, first prepare the solution of known concentration in a burette. Then, add the solution of unknown concentration to a flask with an indicator. Slowly titrate the known solution into the flask until the indicator changes color. Record the volume of the known solution used. Repeat the titration until consistent results are obtained. Calculate the concentration of the unknown solution using the volume and concentration of the known solution.


What test can be used to confirm the presence of chlorine?

Add Silver Nitrate to it and a white precipitate should form