answersLogoWhite

0

Be sure that Windows Firewall is on. Set it to at least medium. You should then be fine.

User Avatar

Wiki User

15y ago

What else can I help you with?

Related Questions

What supplies the voltage to the USB?

The two outside contacts (of four contacts) are connected to the power supply in the computer.


How do the brass contacts mount on a turn signal cam from a 1969 Chevy C-10 There are two different contacts but they can go in either place They must be different for a reason Thanks Terry?

There are 2 contacts. A solid one and one that looks like an arrow that one goes to the outside. Hope this helps


What is potntial and potential free contact?

Potential free contacts (also called "dry contacts") are simply contacts which are physically operated with the main device, but not electrically connected to it. For example a motor contactor often has auxiliary contacts that are operated by the main coil and open and close at the same time as the main contacts but are not used for control of the motor starter. If they are connected to an outside circuit to indicate the status of the starter without being powered by the motor supply they would be considered potential free contacts. These type also called Signal-Contacts. In case of relays and switches if the common/pole is connected internally to a given potential like a 110V phase etc., the contact is not POTENTIAL FREE but if both the common and the normall open (and at time also the normally closed) contacts are presented to the user for connecting in his system as he pleases,the contact is said to be "potential-free".


What is potential and potential free contact?

Potential free contacts (also called "dry contacts") are simply contacts which are physically operated with the main device, but not electrically connected to it. For example a motor contactor often has auxiliary contacts that are operated by the main coil and open and close at the same time as the main contacts but are not used for control of the motor starter. If they are connected to an outside circuit to indicate the status of the starter without being powered by the motor supply they would be considered potential free contacts. These type also called Signal-Contacts. In case of relays and switches if the common/pole is connected internally to a given potential like a 110V phase etc., the contact is not POTENTIAL FREE but if both the common and the normall open (and at time also the normally closed) contacts are presented to the user for connecting in his system as he pleases,the contact is said to be "potential-free".


Is a hull of a boat the floor?

No it's not the Hull is the outside of the boat that contacts the water I believe the floor is called the sole.


Does Tracee Ellis Ross have an eye problem?

Outside of the fact that she needs contacts so she can see better, she does not have an eye condition.


What processes is triggered when blood contacts damaged blood vessels or tissues outside blood vessels?

Clotting factors will be activated.


What is the meaning of sequestering?

Keeping seperate. A jury is sequestered when they are kept seperate from the rest of the world and without any outside contacts.


Do contacts cause floaters?

No, floaters are debris suspended in the semiliquid vitreous humor that fills the eyeball, helping maintain it spherical shape. Everyone has some floaters. Contacts have no effect on the development of floaters (nor do glasses) as they are outside the eyeball thus not in contact with the vitreous humor where the floaters are.


Practice of isolating jurors from any outside contacts that wouls influence their decision in a given case?

A judge may order a jury to be sequestered "Sequestered"


Why did the Tokugawa's shogunate try to limit japans contacts with the outside worlds?

He didn't want other nations to influence his people. He thought the other nations were corrupting Japan.


What is the reading on an ohm meter if a relay is good?

If a relay is functioning properly, an ohm meter should show low resistance (typically close to zero ohms) across the relay's coil terminals when it is energized. For the contacts, the resistance will be low (again, close to zero ohms) when the relay is activated and the contacts are closed, while it should show high resistance (infinite or very high ohms) when the relay is deactivated and the contacts are open. A reading outside of these expected ranges may indicate a faulty relay.