6 mm twin and earth
To answer this question the voltage of the cooker is needed.
7.2kW shower = 32 Amp fuse = 6 mm2 cable size7.5kW shower = 40 Amp fuse = 10 mm2 cable size8.5kW shower = 40 Amp fuse = 10 mm2 cable size9.5kW shower = 40/45 Amp fuse = 10 mm2 cable size10.5kW shower = 45 Amp fuse = 16mm2 cable size
350mcm
25mm cable
Plugs for appliances rated between about 700 watts and 3000 watts (the maximum rating of a wall socket) should be fitted with a 13-amp fuse (coloured brown).
The recommended gauge size for a 100 amp cable is typically 3 AWG (American Wire Gauge) for copper wire.
The recommended cable size for a 200 amp service entrance is typically 2/0 AWG copper or 4/0 AWG aluminum.
To calculate voltage drop to size the wire, a voltage must be stated.
The recommended cable size for a 100 amp electrical circuit is typically 3 AWG copper or 1/0 AWG aluminum.
The recommended size for a 100 amp service entrance cable is typically 2 AWG copper or 1/0 AWG aluminum.
The recommended type and size of cable for a 240-volt, 30-amp circuit is a 2 2 2 4 SER cable.
Yes, the amp rating is a measurement of the highest amp load it should carry. So a 15 amp appliance will work on a 20 amp socket but you wouldn't want to use a 20 amp appliance on a 15 amp socket.