To the best of my knowledge, ADA says to follow NFPA 72 standards. NFPA 72 Standards state that the operable part of the pull station shall be between 3-1/3 ft and 4-1/2 ft.

User Avatar

Wiki User

15y ago

What else can I help you with?

Related Questions

What is the ADA height requirement of fire alarm pull stations placement in NJ?

48" from floor to the middle of the pull station


What is ADA pull force requirements to activate a fire alarm pull station in Pa?

In Pennsylvania, the Americans with Disabilities Act (ADA) requires that fire alarm pull stations be operable with a maximum force of 5 pounds. This requirement ensures that individuals with disabilities can easily access and activate the alarm in case of an emergency. It is important for these pull stations to be installed at appropriate heights and locations to be compliant with accessibility standards.


Where would i find the height requirement in the nfpa 72 fire alarm code?

The height requirement for fire alarm systems can be found in NFPA 72, specifically in Chapter 17, which covers the installation of fire alarm systems. Look for sections that address the positioning of detectors, notification appliances, and other components, as they typically specify mounting heights based on the type of device and the environment. Additionally, consult any applicable annexes for further guidance and recommendations.


What height to install a fire alarm strobe light?

140cm.from floor line


What is the height of the fire alarm Knox box?

There is no standard height but they are generally mounted at eye-level or above, to deter juvenile vandalism.


What was the first alarm clock How did it work?

The first alarm clock was powered by water where if the water was at a certain height, it would go off with a beeping sound.


What is the penal code for pulling a fire alarm in Texas?

In Texas, pulling a fire alarm without cause is considered a criminal offense under Section 42.06 of the Texas Penal Code. This act is classified as a Class A misdemeanor, which can result in penalties including fines and potential jail time. If the false alarm causes significant disruption or risk, it may lead to more severe charges.


What are the benefits of docking stations?

Most docking stations will not only charge the iPod but will allow you to play music through the speakers in the docking station as well.Most docking stations will have other neat features as well such as using the music on the ipod for an alarm or give you a remote to control the ipod from the couch.


What is the requirement of fire alarm pull stations placement in Washington dc?

You must follow NFPA 72:Chapter 17 Initiating Devices17.14 Manually Actuated Alarm-Initiating Devices.17.14.1 Manual fire alarm boxes shall be used only for fire alarm initiating purposes.17.14.1.1* Unless installed in an environment that precludes the use of red paint or red plastic, manual fire alarm boxes shall be red in color.17.14.1.2 Manual pull stations for initiating other than fire alarm shall be permitted if the devices are differentiated from the manual fire alarm boxes by a color other than red and labeling.17.14.1.3 Manual fire alarm boxes shall be mounted on a background of contrasting color.17.14.2 Combination manual fire alarm boxes and guard's signaling stations shall be permitted.17.14.3 Each manual fire alarm box shall be securely mounted.17.14.4 The operable part of each manual fire alarm box shall be not less than 42 in. (1.07 m) and not more than 48 in. (1.22 m) above floor level.17.14.5 Manual fire alarm boxes shall be installed so that they are conspicuous, unobstructed, and accessible.17.14.6 Manual fire alarm boxes shall be located within 60 in. (1.52 m) of the exit doorway opening at each exit on each floor.17.14.7 Manual fire alarm boxes shall be mounted on both sides of grouped openings over 40 ft (12.2 m) in width, and within 60 in. (1.52 m) of each side of the opening.17.14.8* Additional manual fire alarm boxes shall be provided so that the travel distance to the nearest fire alarm box will not be in excess of 200 ft (61.0 m), measured horizontally on the same floor.


Where are fire pull stations required in Ontario?

In Ontario, fire pull stations are required in various locations as per the Ontario Fire Code. They must be installed in all buildings with a fire alarm system, typically positioned near exits and at accessible locations to ensure they can be easily reached in case of an emergency. Additionally, pull stations should be located within a certain distance from any area where people may be present, ensuring prompt activation of the alarm system in the event of a fire.


Are manual fire alarm pull stations required?

Check with your local building department of your city or county. They will be able to tell you exactly what is required in your community.


Are giraffes like alarm systems for other animals?

The height of a Giraffe's head makes them ideal lookouts for approaching predators.