30 amps at 120 volts is 3600 watts.

30 amps at 240 volts is 7200 watts.

User Avatar

Wiki User

12y ago

What else can I help you with?

Related Questions

What size cable for 30 amp cooker socket?

6 mm twin and earth


WHAT IS A 13 AMP COOKER?

Plugs for appliances rated between about 700 watts and 3000 watts (the maximum rating of a wall socket) should be fitted with a 13-amp fuse (coloured brown).


Can you replace your current cooker fuse 30 amp with a 40 amp circuit breaker?

A 30 amp breaker is designed to trip at an earlier point than a larger 40 amp breaker so one appliance that operates on lower amperage level could be unsafe or damaged before it could trip the higher 40 amp breaker. Also, the existing wiring may not be rated for 40 amp service.


What size cable for your 9700 watt cooker?

To answer this question the voltage of the cooker is needed.


What fuse number is for the Anti-lock Brakes 2001 E350?

fuse # 1 20 amp fuse in Central Junction Box


How do you join 12 volt 40 amp wires?

One way to join 12 volt 40 amp wires is with a wire nut cap. The wires are twisted together and then a protective cap is placed over them to ensure they stay joined.


Where are the main fuses for the AC located on a 2000 Ford 350 Van V10?

# 13 15 amp fuse in Central Junction Box


What household product requires 20 amp 240 volt?

Could be a cooker. <<>> In North America the hot water tank uses a 20 amp 240 volt supply. Some deep well farm pumps are also in this range of parameters.


Why are there two 15 amp breakers connected to your 30 amp breaker?

Answer for UK, Europe and countries running a 50 Hz supply service.It is acceptable to connect two 15-amp breakers to a 30-amp supply. It woud also be acceptable in some applications to connect three 15-amp breakers if it were known that the total current would not exceed 30 amps. For example in many UK properties there is a 60-amp supply, and connected to this there are two 30-amp supplies for the ring-circuit and the cooker, plus also a 10-amp lighting supply.


What is the current AMP of a 220V rice cooker?

The amps it draws depends on how big it is. Typically 2-12 amps. Check for a manufacturer's plate that shows the wattage Most of the load in a rice cooker is a resistive heating element, so the amperage will be quite close to the wattage divided by the voltage (220 here).


Hob which has a total of 5.9KW what amp hob cooker switch do you need?

To calculate the amps needed for a 5.9kW hob, use the formula Amps = Watts / Volts. Assuming a standard UK voltage of 230V, the amp requirement would be around 25.65A. Therefore, you would need a cooker switch rated for 30A to ensure proper operation.


2005 f-350 cigarette lighter fuse?

Located in the Central Junction Box(under dashboard on driver side) fuse #12 should be a yellow 20 amp fuse.